A11-positive β-amyloid Oligomer Preparation and Assessment Using Dot Blotting Analysis

Abstract: β-amyloid (Aβ) is a hydrophobic peptide with an intrinsic tendency to self-assemble into aggregates. Among various aggregates, Aβ oligomer is widely accepted as the leading neurotoxin in the progress of Alzheimer's disease (AD) and is considered to be the crucial event in the pathogenesis of AD. Therefore, Aβ oligomer inhibitors might prevent neurodegeneration and have the potential to be developed as disease-modifying treatments of AD. However, different formation protocols of Aβ oligomer might lead to oligom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 10 publications
(4 reference statements)
0
12
0
Order By: Relevance
“…A 50 μM Aβ 1–42 solution was obtained and stored at 4°C. The preparation is the combination of low molecular weight forms of soluble Aβ (Chunhui et al, 2018 ).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A 50 μM Aβ 1–42 solution was obtained and stored at 4°C. The preparation is the combination of low molecular weight forms of soluble Aβ (Chunhui et al, 2018 ).…”
Section: Methodsmentioning
confidence: 99%
“…Then the collected supernatant was kept stirring for 48 h at room temperature. A 50 µM Aβ 1-42 solution was obtained and stored at 4 • C. The preparation is the combination of low molecular weight forms of soluble Aβ (Chunhui et al, 2018).…”
Section: Aβ 1-42 Oligomers Preparationmentioning
confidence: 99%
“…Dot blotting analysis was also carried out according to the methods we reported previously [37]. Firstly, the mixture of equal volume of different concentrations of the drugs and Aβ solution were prepared.…”
Section: Dot Blotting Analysismentioning
confidence: 99%
“…Alternatively, dots can be applied freehand, as has been published by other laboratories (Au - Chunhui et al, 2018 , Tizon et al, 2010 ). In this case, the user should take care to keep the membrane as clean as possible (the infrared detection system is more sensitive to background contamination than other methods such as chemiluminescence ( Schutz-Geschwender et al, 2004 )).…”
Section: Materials and Equipmentmentioning
confidence: 99%