2020
DOI: 10.3390/s20061675
|View full text |Cite
|
Sign up to set email alerts
|

A Wristwatch-Based Wireless Sensor Platform for IoT Health Monitoring Applications

Abstract: A wristwatch-based wireless sensor platform for IoT wearable health monitoring applications is presented. The paper describes the platform in detail, with a particular focus given to the design of a novel and compact wireless sub-system for 868 MHz wristwatch applications. An example application using the developed platform is discussed for arterial oxygen saturation (SpO2) and heart rate measurement using optical photoplethysmography (PPG). A comparison of the wireless performance in the 868 MHz and the 2.45 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
32
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 52 publications
(45 citation statements)
references
References 44 publications
0
32
0
Order By: Relevance
“…From (4), it can be seen that at higher f SW , P PAR is dominant due to its direct proportionality to f SW . Using these losses, PCE is calculated according to (5), where P OUT is the output power. Finally, the voltage conversion efficiency (VCE), shown in (6)…”
Section: B Power Losses and Efficiency Analysismentioning
confidence: 99%
See 3 more Smart Citations
“…From (4), it can be seen that at higher f SW , P PAR is dominant due to its direct proportionality to f SW . Using these losses, PCE is calculated according to (5), where P OUT is the output power. Finally, the voltage conversion efficiency (VCE), shown in (6)…”
Section: B Power Losses and Efficiency Analysismentioning
confidence: 99%
“…For a fixed load impedance, I OUT-avg in the discontinuous operation mode is smaller than its conventional counterpart, due to supplying current only during t NOL . If the P IN drops, the system will reduce P PAR in (4) to maintain the same PCE shown in (5). To accomplish that, f SW is reduced.…”
Section: B Theoretical Analysis Of Maximum Efficiency At Desired Inpmentioning
confidence: 99%
See 2 more Smart Citations
“…In this regard, wearable sensing devices are key factors for revolutionizing healthcare diagnostics and delivery [3,4]. Wearable devices may enable personalized preventative care, by exploiting the early detection of vital sign anomalies in patient to improve healthcare outcomes [5,6] and to allow continuous and remote monitoring of these values [7]. There are numerous biomedical parameters that can be monitored through wearable, portable sensing solutions: electrocardiogram, oxygen saturation, heart rate, blood pressure.…”
Section: Introductionmentioning
confidence: 99%