2021
DOI: 10.3389/fcomp.2021.745831
|View full text |Cite
|
Sign up to set email alerts
|

A Workflow for Rapid Unbiased Quantification of Fibrillar Feature Alignment in Biological Images

Abstract: Measuring the organization of the cellular cytoskeleton and the surrounding extracellular matrix (ECM) is currently of wide interest as changes in both local and global alignment can highlight alterations in cellular functions and material properties of the extracellular environment. Different approaches have been developed to quantify these structures, typically based on fiber segmentation or on matrix representation and transformation of the image, each with its own advantages and disadvantages. Here we pres… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
40
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 31 publications
(41 citation statements)
references
References 35 publications
1
40
0
Order By: Relevance
“…We observed a downward migration of nuclei, increased MG height, and increased overall complexity (as indicated by skeleton distributions), particularly in the IPL. We then examined the alignment of structures in the image ( i.e., horizontal vs vertical) that can be described as image order [35] ( Fig. 6B,C ), which showed a significant difference from 60-to-96 hpf (p=0.0049; Fig.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…We observed a downward migration of nuclei, increased MG height, and increased overall complexity (as indicated by skeleton distributions), particularly in the IPL. We then examined the alignment of structures in the image ( i.e., horizontal vs vertical) that can be described as image order [35] ( Fig. 6B,C ), which showed a significant difference from 60-to-96 hpf (p=0.0049; Fig.…”
Section: Resultsmentioning
confidence: 99%
“…8M ; p=0.0072) data. To further understand this, we performed directionality analysis based on Fourier Transformation as previously described [35] ( Fig. 8N ).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…We tested nine tools that could quantify the alignment of the fibrin network (Supplementary Table II): OrientationJ 27 , CurveAlign 28 , GTFiber 29 , CT-FIRE 24 , Cytospectre 30 , Directionality, FOA tool 31 , FiberFit 32 , and Alignment by Fourier Transform (AFT) 33 . Most of the methods measured global alignment (within the whole image), while OrientationJ, GTFiber, and AFT used local alignment measurements (within the local neighborhood).…”
Section: Resultsmentioning
confidence: 99%
“…If the image in the real space contains aligned and organized features, the corresponding 2D FFT shows an elongated (elliptical) shape in the frequency domain. Conversely, an isotropic signal results in a rounder shape [28]. Measuring the eccentricity of the ellipse in the frequency domain can thus provide a good indicator of cytoskeleton organization.…”
Section: Measure Of Cytoskeletal Fiber Alignmentmentioning
confidence: 99%