2020
DOI: 10.1016/j.ijepes.2020.106032
|View full text |Cite
|
Sign up to set email alerts
|

A wavelet-based hybrid islanding detection system applied for distributed generators interconnected to AC microgrids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
21
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(26 citation statements)
references
References 63 publications
(102 reference statements)
0
21
0
Order By: Relevance
“…For example, [11], [13], [14] inject a noncharacteristic harmonic current of 75 Hz periodically. The settled values of current and voltage are recorded and converted into the frequency domain with Fourier transform analysis (or wavelet transform as per [11]). The voltage and current values at 75 Hz are extracted and the impedance is calculated with Z n (ω h ) = R n + jω h L n (where ω h is the nonharmonic frequency).…”
Section: ) Nonharmonic Excitationmentioning
confidence: 99%
See 2 more Smart Citations
“…For example, [11], [13], [14] inject a noncharacteristic harmonic current of 75 Hz periodically. The settled values of current and voltage are recorded and converted into the frequency domain with Fourier transform analysis (or wavelet transform as per [11]). The voltage and current values at 75 Hz are extracted and the impedance is calculated with Z n (ω h ) = R n + jω h L n (where ω h is the nonharmonic frequency).…”
Section: ) Nonharmonic Excitationmentioning
confidence: 99%
“…Park More recently, some researchers have explored using the Wavelet Transform (WT) as an alternative to FFT [11], [86].…”
Section: Current Controllermentioning
confidence: 99%
See 1 more Smart Citation
“…The passive methods including frequency variations [13,14], degree of alteration of power frequency [15], power and voltage variation ASTESJ ISSN: 2415-6698 [16], energy mismatch and harmonic content recognition [17] and the degree of variation of reactive power [18], these techniques were applied in power grid integrated network for fault diagnostic. Moreover, undetected faults have an undesirable effect on the overall performance of the power grid, the active algorithms used for fault diagnostic includes frequency signal injection [19], singular and dual harmonic current injection [20,21], output power variation [22], reactive power control [23,24], and the impedance measurement method [25,26], these methods were used to detect faults in power grid integrated network with REDGs.…”
Section: Introductionmentioning
confidence: 99%
“…Passive schemes decide based on the local measurements and predefined thresholds without any changes in MGs, while active schemes usually inject perturbations to MGs to decide based on the consequent changes in local measurements [15,16]. A hybrid scheme is a combination of passive and active schemes [17,18]. Among the various local islanding detection schemes, passive schemes have the lowest cost, lowest complexity, and highest detection speed and, unlike active schemes, do not have negative effects on power quality [6].…”
mentioning
confidence: 99%