2019
DOI: 10.1007/s00604-019-3638-8
|View full text |Cite
|
Sign up to set email alerts
|

A voltammetric immunoassay for the carcinoembryonic antigen using silver(I)-terephthalate metal-organic frameworks containing gold nanoparticles as a signal probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 27 publications
(9 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…The authors emphasized that the sensor could be used for the POCT of CEA from human serum. Aside from MNP-carbon material-based composites, metal oxide NPs, core shell MNPs, quantum dot NPs, graphene, MOF, etc., have extensively been studied as the electrode probes for fabricating both labeled or label-free sandwich immunosensing arrays for the ultrasensitive detection of CEA for early-stage cancer diagnoses [196,202,209,[211][212][213][214][215][216].…”
Section: Mnps In Cancer Biomarker Detectionmentioning
confidence: 99%
“…The authors emphasized that the sensor could be used for the POCT of CEA from human serum. Aside from MNP-carbon material-based composites, metal oxide NPs, core shell MNPs, quantum dot NPs, graphene, MOF, etc., have extensively been studied as the electrode probes for fabricating both labeled or label-free sandwich immunosensing arrays for the ultrasensitive detection of CEA for early-stage cancer diagnoses [196,202,209,[211][212][213][214][215][216].…”
Section: Mnps In Cancer Biomarker Detectionmentioning
confidence: 99%
“…24 The broad band centered around 3000 cm À1 in the TP spectrum disappears in ATP, indicating the formation of the O-Ag bond. 25 The O-Ag bond is further confirmed from the characteristic weak peak observed at 504 cm À1 , while the peak at 740 cm À1 corresponds to COO-bending.…”
Section: Resultsmentioning
confidence: 81%
“…Therefore, the fluorescence intensity of Ag-MOFs in the lysosome gradually increased with time (0–48 h), indicating that Ag-MOF can locate the drug through its own fluorescence characteristics. It has been reported that the synthesized Ag-MOFs were composed of different organic ligands. However, none of the above Ag-MOFs reported fluorescence characteristics. Hence, we reported for the first time that the constructed Ag-MOFs have fluorescence characteristics; second, PFK15 in Ag-MOFs present an acid-response release, which was especially suitable for tumor weak acidic environment.…”
Section: Discussionmentioning
confidence: 99%