A Virtual Instrument for Automated Measurement of Arterial Compliance

Abstract: Measurement of arterial distensibility is very important in cardiovascular diagnosis for early detection of coronary heart disease and possible prediction of future cardiac events. Conventionally, B-mode ultrasound imaging systems have been used along with expensive vessel wall tracking systems for estimation of arterial distension and calculation of various estimates of compliance. We present a simple instrument for noninvasive in vivo evaluation of arterial compliance using a single element ultrasound transd… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
36
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
4
2

Relationship

4
2

Authors

Journals

citations
Cited by 36 publications
(36 citation statements)
references
References 20 publications
0
36
0
Order By: Relevance
“…The artery detection algorithm has been validated to be capable of detecting artery locations with sensitivity more than 90 % even for SNR as low as 5 dB in the normal range of expected wall motion frequencies between 0.5 -4 Hz [7]. The correlation based wall tracking algorithm has also been independently shown have error less than 10 % [6]. ARTSENS performs synchronized transducer excitation and data capture, and integrates wall detection and tracking algorithms along with on-the-fly distension waveform analysis to enable quick in-vivo measurements.…”
Section: B Automated Measurement Of Arterial Compliancementioning
confidence: 99%
See 4 more Smart Citations
“…The artery detection algorithm has been validated to be capable of detecting artery locations with sensitivity more than 90 % even for SNR as low as 5 dB in the normal range of expected wall motion frequencies between 0.5 -4 Hz [7]. The correlation based wall tracking algorithm has also been independently shown have error less than 10 % [6]. ARTSENS performs synchronized transducer excitation and data capture, and integrates wall detection and tracking algorithms along with on-the-fly distension waveform analysis to enable quick in-vivo measurements.…”
Section: B Automated Measurement Of Arterial Compliancementioning
confidence: 99%
“…A detailed explanation of the various steps in the automated measurement algorithm may be found elsewhere [6], [7]. The artery detection algorithm has been validated to be capable of detecting artery locations with sensitivity more than 90 % even for SNR as low as 5 dB in the normal range of expected wall motion frequencies between 0.5 -4 Hz [7].…”
Section: B Automated Measurement Of Arterial Compliancementioning
confidence: 99%
See 3 more Smart Citations