2018
DOI: 10.1016/j.nima.2017.10.003
|View full text |Cite
|
Sign up to set email alerts
|

A versatile triple radiofrequency quadrupole system for cooling, mass separation and bunching of exotic nuclei

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 31 publications
(23 citation statements)
references
References 56 publications
0
23
0
Order By: Relevance
“…In Fig. 2, a schematic view of the FRS-IC with its three main parts is shown: (i) the gas-filled cryogenic stopping cell (CSC) [29][30][31][32] for thermalization of the exotic nuclei produced at relativistic energies, (ii) a beamline, based on radio frequency quadrupoles (RFQ) [32][33][34][35] for mass-selective transport and differential pumping, equipped with detectors (channeltrons and silicon detectors) for ion counting and α-decay spectroscopy and with ion sources for diagnostic purposes, and (iii) the MR-TOF-MS [14,36,37] for several purposes, such as diagnostics of the upstream beamline, ion identification and counting, and direct mass measurements.…”
Section: Methodsmentioning
confidence: 99%
“…In Fig. 2, a schematic view of the FRS-IC with its three main parts is shown: (i) the gas-filled cryogenic stopping cell (CSC) [29][30][31][32] for thermalization of the exotic nuclei produced at relativistic energies, (ii) a beamline, based on radio frequency quadrupoles (RFQ) [32][33][34][35] for mass-selective transport and differential pumping, equipped with detectors (channeltrons and silicon detectors) for ion counting and α-decay spectroscopy and with ion sources for diagnostic purposes, and (iii) the MR-TOF-MS [14,36,37] for several purposes, such as diagnostics of the upstream beamline, ion identification and counting, and direct mass measurements.…”
Section: Methodsmentioning
confidence: 99%
“…The RFQ beam line and MR-TOF-MS will be based on instruments that are experimentally demonstrated. The RFQ beam line may be ~1 m long, and its expected transmission will be ~90% [125]. The MR-TOF-MS may be of similar length, and its expected efficiency will be ~50% [126].…”
Section: Study Of Neutron-rich Fission Fragments and Relation To The mentioning
confidence: 99%
“…Thermalization is performed in a cryogenic stopping cell (CSC) [17][18][19]. The isotopes are then extracted, diagnosed and transported by a versatile RFQ beam-line [20]. Their mass is measured precisely with a multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) [21] that can also provide an isobarically (and isomerically) clean beam for further experiments [22].…”
Section: Description Of the Methodsmentioning
confidence: 99%