A versatile automated sample changer for texture measurements on the high pressure-preferred orientation neutron diffractometer

Abstract: An automated sample changer with an Eulerian cradle for neutron texture measurements is described. This device has been measuring over 2300 texture and almost 400 powder samples at ambient conditions since it became operational in 2002 for use in the high pressure-preferred orientation diffractometer at the LANSCE neutron scattering facility. Operation for almost a decade resulted in sustained enhancements of mechanics, electronics, and software which significantly improved reliability and resiliency. We also … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 30 publications
0
8
0
Order By: Relevance
“…The present study was focused on the neutron diffraction measurements of an Al alloy containing 2% Mg, in order to determine the kinetics of recrystallization by ex situ and in-situ annealing. The experiments were conducted on two time-of-flight (TOF) neutron diffraction instruments: the engineering diffractometer (VULCAN) at Oak Ridge National Laboratory (ORNL, Oak Ridge, TN, USA) [39], and at the high-pressure-preferential orientation (HIPPO) at Los Alamos National Laboratory (LANL, Los Alamos, NM, USA) [40][41][42]. The detailed analysis included the texture characterizations of DF and RCX along with developing a new method for texture decomposition.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The present study was focused on the neutron diffraction measurements of an Al alloy containing 2% Mg, in order to determine the kinetics of recrystallization by ex situ and in-situ annealing. The experiments were conducted on two time-of-flight (TOF) neutron diffraction instruments: the engineering diffractometer (VULCAN) at Oak Ridge National Laboratory (ORNL, Oak Ridge, TN, USA) [39], and at the high-pressure-preferential orientation (HIPPO) at Los Alamos National Laboratory (LANL, Los Alamos, NM, USA) [40][41][42]. The detailed analysis included the texture characterizations of DF and RCX along with developing a new method for texture decomposition.…”
Section: Methodsmentioning
confidence: 99%
“…Given the fact that optical microscopy showed a fully recrystallized structure after annealing for 20 min at 360 • C, the in-situ isothermal annealing treatments were performed in the temperature range from 250 to 360 • C, and the annealing times from 20 to 210 min. The in-situ isochronal annealing was performed at two TOF neutron diffractometers, HIPPO and VULCAN, for two heating rates with nominal values of 2 • C/min and 7 • C/min, and in the temperature span from room temperature to 400 • C. HIPPO is a TOF instrument dedicated for texture measurements [40][41][42][43][44][45][46], while at VULCAN engineering diffractometer, the texture characterizations and the corresponding data analysis were developed as a complementary capability [47,48].…”
Section: Neutron Diffraction Texture Characterizationsmentioning
confidence: 99%
“…The samples were mounted on sample holders and measured at rotation angles of 0, 45, 67.5 and 90 degrees around the sample cylinder axis using an automated sample changer [32]. Neutrons were detected by 3 He detector tubes grouped on 30 detector panels arranged on three rings with nominal diffraction angles of 140, 90 and 40 degrees.…”
Section: Texture Measurementmentioning
confidence: 99%
“…As an example, Figure 6 shows the texture evolution in Zr-2.5Nb measured on the HIPPO diffractometer [77,78] using a high-temperature deformation furnace [79]. The texture of the 6 mm diameter and 20 mm long sample was measured at room temperature before and after the high-temperature deformation on a robotic sample changer [80] as a benchmark. During the furnace experiment, the texture was measured at 250 ∘ C, 625 ∘ C, 815 ∘ C, and 975 ∘ C, and then the sample was compressed by 20%, followed again by texture measurements at the same temperatures during cooling.…”
Section: Deformation Studiesmentioning
confidence: 99%