2017
DOI: 10.1016/j.jchromb.2017.10.040
|View full text |Cite
|
Sign up to set email alerts
|

A validated UPLC–MS/MS method for biomonitoring the exposure to the fragrance 7-hydroxycitronellal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…As validation parameters, linearity, specificity, recovery, precision, and accuracy were tested. Precision and accuracy were always limited to at least 20%, but more often more stringent margins were used such as 15% (Asimakopoulos et al 2013a ; Stoeckelhuber et al 2017 ) or even 10% (Bhandari et al 2019 ; Höllerer et al 2018b ; Schettgen et al 2017 ). Lépine et al assessed the method’s accuracy by comparing the results with the samples from an external quality control assessment, such as the German External Quality Assessment Scheme (G-EQUAS).…”
Section: Sample Preparation and Analytical Methods For The Determinat...mentioning
confidence: 99%
See 3 more Smart Citations
“…As validation parameters, linearity, specificity, recovery, precision, and accuracy were tested. Precision and accuracy were always limited to at least 20%, but more often more stringent margins were used such as 15% (Asimakopoulos et al 2013a ; Stoeckelhuber et al 2017 ) or even 10% (Bhandari et al 2019 ; Höllerer et al 2018b ; Schettgen et al 2017 ). Lépine et al assessed the method’s accuracy by comparing the results with the samples from an external quality control assessment, such as the German External Quality Assessment Scheme (G-EQUAS).…”
Section: Sample Preparation and Analytical Methods For The Determinat...mentioning
confidence: 99%
“…Dried and derivatized with 3-NPA in WA (80 °C, 30 min) UPLC: Waters Acquity UPLC I-Class Column: Waters Acquity BEH C18 (100 mm × 2.1 mm, 1.7 μm) Mobile phases: A (MeOH), B (5 mM ammonium acetate with 0.025% ammonium hydroxide, pH 9.2), flow 0.35 mL/min Gradient elution: 80% B, 0–4 min, 80–55% B, 4–10 min, 55–35% B, 10–11 min, 35–0% B, 11–11.1 min, 0% B, 11.1–13 min, 0–80% B, 13–13.1 min, 80% B, 13.1–15 min ESI(-)-MS2-MRM: Waters TQ-S Triple Quadrupole 0.42, 0.1, 0.36, 0.45, 0.39 Pluym et al ( 2016 ) 7-HC 7-HCA LLE: 1 mL urine deconjugated (37 °C, 3 h), acidified and extracted with DCM. Dried and derivatized with 3-NPA (80 °C, 30 min) UPLC: Waters Acquity UPLC I-Class Column: Waters Acquity BEH C18 (100 mm × 2.1 mm, 1.7 μm) Mobile phases: A (0.1% FA/W), B (0.1% FA/ACN), flow 0.5 mL/min Gradient elution: 80% A, 0–1 min, 80–20% a, 1–5 min, 20% A, 5–5.5 min, 20–80% A, 5.5–7 min ESI(-)-MS2-MRM: Waters TQ-S Triple Quadrupole 0.5 Stoeckelhuber et al ( 2017 ) Benzotriazoles and benzothiazoles 1H-BTR , 1OH-BTR, TTR, XTR, 5-Cl-1H-BTR, BTH, 2-OH-BTH, 2-MeS-BTH, 2-amino-BTH, 2-SH-BTH, 2-SCNMeS-BTH 1H-BTR , 1OH-BTR, TTR, XTR, 5-Cl-1H-BTR, BTH, 2-OH-BTH, 2-MeS-BTH, 2-amino-BTH, 2-SH-BTH, 2-SCNMeS-BTH SPE: 2 mL, deconjugation with β-glucuronidase (37 °C, 24 h), diluted, pH adjusted to 3, extracted on Oasis HLB 6 cc/200 mg with MeOH/ACN (1:1), dried and reconstituted in 200 μL MeOH/ACN (1:1) LLE: 600 μL extracted with 6 mL ACN/DCM (1:1), extract dried and reconstituted in 150 μL MeOH/ACN HPLC: Agilent 1100 HPLC Column: Zorbax SB aq (150 × 2.1 mm, 3,5 μm), Mobile phases: A (0.1% FA/W), B (ACN), flow 0.25 mL/min Gradient elution: 10–40% B, 4.5 min, 40–100% B, 11.5 min, 100% B, 6.1 min, 10% B, 7.1 min ESI(+)-MS2-MRM:Applied Biosystems triple quadrupole SPE: 0.50, 2.00, 0.20, 0.20, 0.50, 5.00, 2.50, 0.20, 0.20, 0.50 LLE: 1.70, 0.70, 0.70, 1.70, 0.70. 17.00, 3.50, 1.70, 0.70, 1.70 Asimakopoulos et al ( 2013a ) 1H-BTR , 1OH-BTR, TTR, XTR, 5-Cl-1H-BTR, BTH, 2-OH-BTH, 2-MeS-BTH, 2-amino-BTH, 2-SCNMeS-BTH 1H-BTR , 1OH-BTR, TTR, XTR, 5-Cl-1H-BTR, BTH, 2-OH-BTH, 2-MeS-BTH, 2-amino-BTH, 2-SCNMeS-BTH LLE: 1 mL deconjugated with β-glucuronidase (37 °C, 24 h), extracted with 3 mL MTBE/EA (5/1), dried and reconstituted in 200 μL ACN/W (6/4) UPLC: Dionex Ultimate 3000 UHPLC Column: Thermo Hypersil GOLD (100 × 2.1 mm, 1.9 μm) Mobile phases: A (0.01% FA/W), B (ACN), flow 0.25 mL/min Gradient elution: 10–83% B, 9.5 min, 83–100%, 100% B, 3 min, 10% B ESI(+)-MS2-MRM: Thermo Scientific TSQ Quantiva Triple Quadrupole 0.2, 11, 2, 7, 4, 9, 6, 11, 4, 14 Li et al ( 2017 ...…”
Section: Sample Preparation and Analytical Methods For The Determinat...mentioning
confidence: 99%
See 2 more Smart Citations