2020
DOI: 10.3390/s20185380
|View full text |Cite
|
Sign up to set email alerts
|

A Usability Study of Physiological Measurement in School Using Wearable Sensors

Abstract: Measuring psychophysiological signals of adolescents using unobtrusive wearable sensors may contribute to understanding the development of emotional disorders. This study investigated the feasibility of measuring high quality physiological data and examined the validity of signal processing in a school setting. Among 86 adolescents, a total of more than 410 h of electrodermal activity (EDA) data were recorded using a wrist-worn sensor with gelled electrodes and over 370 h of heart rate data were recorded using… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
42
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 30 publications
(42 citation statements)
references
References 64 publications
0
42
0
Order By: Relevance
“…Normalization of the EDA signal can also be done by using a baseline to correct for variation between individuals ( n = 13) [ 12 , 30 ]. In the literature, the tonic component of EDA is referred to as the baseline as well [ 3 , 35 ], but here we discuss the specific measurement of a baseline.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Normalization of the EDA signal can also be done by using a baseline to correct for variation between individuals ( n = 13) [ 12 , 30 ]. In the literature, the tonic component of EDA is referred to as the baseline as well [ 3 , 35 ], but here we discuss the specific measurement of a baseline.…”
Section: Resultsmentioning
confidence: 99%
“…Previous research has recognized EDA as a reliable identifier of physiological arousal [ 12 ]. There is a substantial increase in the usability and accessibility of devices that measure EDA [ 3 , 30 ], and wearable technologies provide more opportunities to measure EDA in real-world settings [ 4 , 31 ]. EDA holds promise for measuring arousal during learning, as it represents a close to real-time activation that can possibly be linked to cognitive and emotional responses on a detailed basis [ 3 , 27 , 32 ].…”
Section: Introductionmentioning
confidence: 99%
“…In addition, the tools should be tested to confirm that they are reliable to be used in practice. In the current project, for example, we were able to test wearable devices that measured heart rate and skin conductance in school settings ( Thammasan et al, 2020 ; Stuldreher et al, 2021 ). This allowed us to test the reliability of these measurements compared to laboratory settings and equipment ( evaluation ).…”
Section: Best Practicesmentioning
confidence: 99%
“…The measurement is highly precise on a single device but cannot yet measure the full scope of mediated activities that occur on multiple devices. In a laboratory environment, physiological measures of heartrate and skin conductance can be collected, but even the most modern sensors fail to capture accurate physiological data in natural settings for periods of time beyond a few hours (Labonte- LeMoyne et al, 2018;Thammasan et al, 2020). To capture effects of media use over the course of several days, psychological measures are the only viable option.…”
Section: Emamentioning
confidence: 99%