2017
DOI: 10.3390/en10122133
|View full text |Cite
|
Sign up to set email alerts
|

A Two-Level Optimal Scheduling Strategy for Central Air-Conditioners Based on Metal Model with Comprehensive State-Queueing Control Models

Abstract: Unlike some thermostatically controlled appliances (TCAs) with small capacities, Central Air-conditioner (CAC) has huge potential for demand response because of its large capacity. This paper presents a new CAC control strategy under multiple constraints. The CAC is modeled by three main modules: CAC central unit, water pumps, and temperature simulation of terminal users. The CAC's power consumption is mainly determined by users' load ratio. As the information and communication system have become the central n… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 23 publications
0
5
0
Order By: Relevance
“…From Figure 3, it can be seen that the indoor temperature is constant after the inverter air conditioner participates in the demand response at t Iac_on_1 (t Iac_on_2 ), which proves the correctness of the temperature maintenance strategy presented in this paper. It can be seen, from (17), that the VSOC largely depends on the current indoor temperature. When the indoor temperature remains unchanged, the value of VSOC also remains constant.…”
Section: Ves Control Model For Inverter Air Conditionersmentioning
confidence: 98%
See 4 more Smart Citations
“…From Figure 3, it can be seen that the indoor temperature is constant after the inverter air conditioner participates in the demand response at t Iac_on_1 (t Iac_on_2 ), which proves the correctness of the temperature maintenance strategy presented in this paper. It can be seen, from (17), that the VSOC largely depends on the current indoor temperature. When the indoor temperature remains unchanged, the value of VSOC also remains constant.…”
Section: Ves Control Model For Inverter Air Conditionersmentioning
confidence: 98%
“…Therefore, it has been verified that the proposed control strategy can achieve load reduction from inverter air conditioners. It can be seen, from (17), that the VSOC is inversely proportional to From Figure 4, it can be seen that the response power (i.e., the actual amount of load reduction) could fully meet the power shortage (i.e., the load reduction target) during the transfer of control rights. There was a slightly excessive response, but the response power gradually stabilized with time.…”
Section: Control Strategy and Algorithm Casesmentioning
confidence: 98%
See 3 more Smart Citations