2002
DOI: 10.1016/s0017-9310(02)00086-8
|View full text |Cite
|
Sign up to set email alerts
|

A two-dimensional fin efficiency analysis of combined heat and mass transfer in elliptic fins

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
23
0

Year Published

2002
2002
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 62 publications
(24 citation statements)
references
References 13 publications
1
23
0
Order By: Relevance
“…The most widely operated heat exchangers make use of fin-and-tube configuration in association with the application of heating, ventilating, air-conditioning and refrigeration systems. With regard to the fin temperature and dew point temperature of surrounding air, three situations on a fin surface can be distinguished [1]. The fin surface is fully dry if the temperature of the whole fin is higher than the air dew point temperature.…”
Section: List Of Symbols C Pamentioning
confidence: 99%
See 1 more Smart Citation
“…The most widely operated heat exchangers make use of fin-and-tube configuration in association with the application of heating, ventilating, air-conditioning and refrigeration systems. With regard to the fin temperature and dew point temperature of surrounding air, three situations on a fin surface can be distinguished [1]. The fin surface is fully dry if the temperature of the whole fin is higher than the air dew point temperature.…”
Section: List Of Symbols C Pamentioning
confidence: 99%
“…As mentioned earlier, the sensible heat transfer coefficient is often assumed uniform. Thus, the wet fin efficiency is usually determined under this assumption and by introducing a functional relation between the relative humidity and the fin temperature [1,2,[7][8][9][10]. The most proposed relation between ''the difference of the air humidity ratio and that evaluated at the fin temperature'' and ''the difference of the ambient temperature and fin temperature'' used a factor named the condensation factor.…”
Section: List Of Symbols C Pamentioning
confidence: 99%
“…The results reveal that as the slope increases the heat loss decreases and maximum observed the heat loss is for rectangular fins. Lin and Jang (2002) presented the analysis an elliptic fin under the dry, partially wet and fully wet conditions for a range of value for axis ratios, Biot numbers, and air humidifies. It is shown that the fin efficiencies increase as the axis ratio is increased for a particular axis ratio, the efficiency decreases with decrease in fin height or increase in Biot number.…”
Section: Introductionmentioning
confidence: 99%
“…An equivalent convection heat transfer term for fully wet conditions was added to impact the heat transfer, owing to the condensation latent heat. There have been few analyses of the fin efficiency for fully wet conditions, though there have been many studies [22][23][24][25][26][27][28][29] turning to the fin efficiency values. Some design manuals [12] and many experimental studies [24] have used the Schmidt model for dry conditions and the McQuiston model [12,13] for fully wet conditions.…”
Section: Introductionmentioning
confidence: 99%