2023
DOI: 10.1016/j.jphotochem.2022.114493
|View full text |Cite
|
Sign up to set email alerts
|

A “turn-on” fluorescent chemosensor for the meticulous detection of gallium (III) ion and its use in live cell imaging, logic gates and keypad locks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 55 publications
0
6
0
Order By: Relevance
“…The binding stoichiometries of NHPyTSC toward Hg 2+ and Zn 2+ ions were assessed using Job′s plot method . In an ACN/water (8:2, v/v) medium, equal concentrations (1:1, 1 × 10 –5 M) of the sensor NHPyTSC and Hg 2+ /Zn 2+ were collected.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The binding stoichiometries of NHPyTSC toward Hg 2+ and Zn 2+ ions were assessed using Job′s plot method . In an ACN/water (8:2, v/v) medium, equal concentrations (1:1, 1 × 10 –5 M) of the sensor NHPyTSC and Hg 2+ /Zn 2+ were collected.…”
Section: Resultsmentioning
confidence: 99%
“…The binding stoichiometries of NHPyTSC toward Hg 2+ and Zn 2+ ions were assessed using Job′s plot method. 32 In an ACN/water (8:2, v/v) medium, equal concentrations (1:1, 1 × 10 −5 M) of the sensor NHPyTSC and Hg 2+ /Zn 2+ were collected. The concentration of NHPyTSC ranged from 0.1 × 10 −5 to 1 × 10 −5 M. A 1:1 stoichiometry of NHPyTSC-Hg 2+ and NHPyTSC-Zn 2+ complexes was confirmed by Job′s plot, which stated that the peak absorption intensity was seen at 0.5 mole fractions (Figure S10A).…”
Section: ■ Introductionmentioning
confidence: 99%
“…The detection limits were 3.35 nM. The chemosensor PyAP is dependent on the photo-induced electron transfer (PET) mechanism [59].…”
Section: Typical Optical Sensing Strategies 51 Fluorescence Sensing S...mentioning
confidence: 99%
“…Importantly, luminescence-based sensors can be further designed to attain a wide range of signaling "antenna" when the analyte covalently binds to the luminescent probe providing opportunities to monitor the concentrations of the target within a short time. This antenna can be observed through changes in the signal's intensities, wavelength, lifetime, and chirality [28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…When the target analyte binds to the receptor, an immediate change to the emission occur where emission intensity may be enhanced or quenched making 'off-on' or 'on-off' sensors as illustrated in Scheme 1. Variations to the emission spectra may occurs through various mechanisms including PET, Ligand-tometal charge transfer (LMCT), or metal-to-ligand charge transfer (MLCT) [30][31][32][33][34]. Several studies reported that the LMCT involves electronic transitions from the localized orbitals in the conjugated linker to a metalcentered orbital and is highly sensitive to the ionic size and the coordination geometry of the linker [30][31][32][33][34][35][36][37].…”
Section: Introductionmentioning
confidence: 99%