2022
DOI: 10.1016/j.ejmp.2022.05.006
|View full text |Cite
|
Sign up to set email alerts
|

A tin filter’s dose reduction effect revisited: Using the detectability index in low-dose computed tomography for the chest

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…Another study evaluated the dose reduction and diagnostic performance of a Sn filter in 44 colorectal cancer patients who underwent Sn filtered 100 kV and standard 120 kV CT on different days, indicating a substantial reduction of 89% in radiation dose, while maintaining good diagnostic performance. 45 On the other hand, in a phantom study,Hasegawa et al 46 reported a lower dose reduction (22%−25%) with the Sn filter. However, a comparison with the present data is difficult as they used a Filtered Back Projection (FBP) reconstruction algorithm, and the dose reduction in all studies mentioned was achieved whilst maintaining the quality of the CT images for diagnostic purposes.…”
Section: Discussionmentioning
confidence: 96%
See 1 more Smart Citation
“…Another study evaluated the dose reduction and diagnostic performance of a Sn filter in 44 colorectal cancer patients who underwent Sn filtered 100 kV and standard 120 kV CT on different days, indicating a substantial reduction of 89% in radiation dose, while maintaining good diagnostic performance. 45 On the other hand, in a phantom study,Hasegawa et al 46 reported a lower dose reduction (22%−25%) with the Sn filter. However, a comparison with the present data is difficult as they used a Filtered Back Projection (FBP) reconstruction algorithm, and the dose reduction in all studies mentioned was achieved whilst maintaining the quality of the CT images for diagnostic purposes.…”
Section: Discussionmentioning
confidence: 96%
“…Another study evaluated the dose reduction and diagnostic performance of a Sn filter in 44 colorectal cancer patients who underwent Sn filtered 100 kV and standard 120 kV CT on different days, indicating a substantial reduction of 89% in radiation dose, while maintaining good diagnostic performance 45 . On the other hand, in a phantom study, Hasegawa et al 46 . reported a lower dose reduction (22%−25%) with the Sn filter.…”
Section: Discussionmentioning
confidence: 99%
“…Several previous [18][19][20] studies have evaluated the dosage and image quality of low-dose chest CT scans using a tin filter. A study 21 reported that the use of a tin filter resulted in dose reduction ranging from 22% to 25%. The area under the NPS curve decreased by 13% to 17% with the tin filter compared with that without the tin filter.…”
Section: Discussionmentioning
confidence: 99%
“…The removable filters are useful to absorb low-energy photons and thus to significantly reduce radiation exposure to the patient not only in the CT scan but also in topograms. [10][11][12][13][14][15][16][17][18][19][20][21][22] The effect of dose reduction is summarized in Table 2. Whether to use a PSP or whether to scan without the filter depends on the imaging task and on patient size.…”
Section: Prefiltersmentioning
confidence: 99%
“…Siemens has a long history in tin prefiltration and offers changeable tin filters in different thicknesses on many systems. The removable filters are useful to absorb low-energy photons and thus to significantly reduce radiation exposure to the patient not only in the CT scan but also in topograms 10–22 . The effect of dose reduction is summarized in Table 2.…”
Section: Prefiltersmentioning
confidence: 99%