2020
DOI: 10.1016/j.forsciint.2020.110506
|View full text |Cite
|
Sign up to set email alerts
|

A threshold LC–MS/MS method for 92 analytes in oral fluid collected with the Quantisal® device

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…Quantisal® is also known to exhibit higher extraction recovery and good reproducibility for many drugs of abuse and drugs like antipsychotics 36–38 . However, it has been reported that compounds like polyglycols present in the stabilizing buffer can hamper the MS detection 39 . Therefore, we compared Quantisal® buffer and a homemade mix containing ACN/H 2 O (50/50 v/v) + 2% acetic acid.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Quantisal® is also known to exhibit higher extraction recovery and good reproducibility for many drugs of abuse and drugs like antipsychotics 36–38 . However, it has been reported that compounds like polyglycols present in the stabilizing buffer can hamper the MS detection 39 . Therefore, we compared Quantisal® buffer and a homemade mix containing ACN/H 2 O (50/50 v/v) + 2% acetic acid.…”
Section: Resultsmentioning
confidence: 99%
“…[36][37][38] However, it has been reported that compounds like polyglycols present in the stabilizing buffer can hamper the MS detection. 39 Therefore, we compared Quantisal ® buffer and a homemade mix containing ACN/H 2 O (50/50 v/v) + 2% acetic acid.…”
Section: Sample Collectionmentioning
confidence: 99%
“…In specific experiments it was concluded that the loss of benzodiazepines, especially FLU and clonazepam, during natural storage is mainly due to irreversible adsorption of the substances on the collection device, and that pre‐addition of methanol to the collection device can significantly improve this state and achieve maximum stability. In 2020, also employing Quantisal™ collection OF, Desharnais and coworkers established a qualitative LC‐MS/MS decision point analysis method with high throughput and greater stability to monitor and validate the presence of benzodiazepines and metabolites [63] . This method was mainly optimized for the precipitation solvent used (acetone: acetonitrile 30 : 70 V: V), which dramatically improved the stability of FLU and 7AF.…”
Section: Detection Strategy Of Flumentioning
confidence: 99%
“…In 2020, also employing Quantisal™ collection OF, Desharnais and coworkers established a qualitative LC-MS/MS decision point analysis method with high throughput and greater stability to monitor and validate the presence of benzodiazepines and metabolites. [63] This method was mainly optimized for the precipitation solvent used (acetone: acetonitrile 30 : 70 V: V), which dramatically improved the stability of FLU and 7AF.…”
Section: Conventional Lc-ms-based Detection Systemmentioning
confidence: 99%
“…However, OF analysis faces the same challenges observed for conventional biosamples, namely: the low concentration of the analytes and the high presence of interferents. 15 The extraction of TCAs from OF by solid-phase extraction 16 and liquid–liquid extraction 17 has been reported as suitable approaches to overcome both issues.…”
Section: Introductionmentioning
confidence: 99%