2007
DOI: 10.1109/tie.2007.894782
|View full text |Cite
|
Sign up to set email alerts
|

A Three-Phase UPS That Complies With the Standard IEC 62040-3

Abstract: This paper proposes a down-sampled discrete-time internal-model-based controller in the synchronous reference frame with a reduced number of poles. This controller is suitable for three-phase pulsewidth modulation inverters with output transformer for double-conversion uninterruptible power supply applications. It is demonstrated that the use of a down-sampled rate and fewer poles in the internal model results in a number of benefits, among which are the following: 1) improvement of the transient response; 2) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
25
0
10

Year Published

2009
2009
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 78 publications
(36 citation statements)
references
References 19 publications
1
25
0
10
Order By: Relevance
“…The value of THD is computed to be 3.47%. The low value of THD validates the sinusoidal current waveform and is well within the limit of the harmonic standard [9][10].…”
Section: Fig 5 Power Factor and Thd Analysissupporting
confidence: 63%
“…The value of THD is computed to be 3.47%. The low value of THD validates the sinusoidal current waveform and is well within the limit of the harmonic standard [9][10].…”
Section: Fig 5 Power Factor and Thd Analysissupporting
confidence: 63%
“…This form is similar to the stability judgment criteria in [7], such that the conclusion of conventional RC stability judgment can also be applied in the (4k ± 1)-order RC strategy. The stability judgment equation is expressed in Eq.…”
Section: A (4k ± 1)-order Rcmentioning
confidence: 99%
“…Repetitive control (RC), which is based on the internal model principle [5], can track any periodic signal and eliminate the steady-state tracking error. In [6] and [7], the digital form of the RC internal model is 1/(1 − Z −N ), and the fundamental time delay is Z −N , which means that the RC controller will not act in the first period when the instruction changes. Thus, the dynamic response of the RC controller is not satisfying and is suitable for fast-transient applications.…”
Section: Introductionmentioning
confidence: 99%
“…Para comparar com os limites da norma, a tensão eficaz após o início transitório deve ser amostrada com frequência mínima de 10 kHz [68] em uma janela de meio-ciclo da rede [69]. O erro da tensão eficaz é comparado com os limites das classes de resposta transitória da IEC 62040-3.…”
Section: ) Faixa De Tensão E Frequênciaunclassified