1988
DOI: 10.1016/1359-0197(88)90222-6
|View full text |Cite
|
Sign up to set email alerts
|

A thin film recording medium for use in food irradiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
39
0
2

Year Published

1992
1992
2011
2011

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 42 publications
(42 citation statements)
references
References 12 publications
1
39
0
2
Order By: Relevance
“…A transition in the structure of the diacetylene backbone is accompanied by a shift in the absorption peaks, and by a change in length of polymer chain. 25 Such a rearrangement is observed in MD-55 with increased dose 10,21,26,27 and with temperature. 10,11,28 A shift in absorption peak with dose was not observed for EBT film, 12 which leads to a belief that the conformation of atoms comprising the polymer backbone of the LiPCDA polymer formed within EBT film is similar to the backbone of the monomer chain.…”
Section: Ia Chemical Background and General Experiencementioning
confidence: 88%
“…A transition in the structure of the diacetylene backbone is accompanied by a shift in the absorption peaks, and by a change in length of polymer chain. 25 Such a rearrangement is observed in MD-55 with increased dose 10,21,26,27 and with temperature. 10,11,28 A shift in absorption peak with dose was not observed for EBT film, 12 which leads to a belief that the conformation of atoms comprising the polymer backbone of the LiPCDA polymer formed within EBT film is similar to the backbone of the monomer chain.…”
Section: Ia Chemical Background and General Experiencementioning
confidence: 88%
“…These results were in good agreement with the finding of Giles and Murphy, 27 who had shown that XR type films are dose-rateindependent within 5%. In an independent investigation, Saylor et al 21 showed 5% variation in optical densities of HD-810 film for dose rates ranging from 0.02 to 200 Gy/ min. However, many of the reports in the literature pertain to older films that are not useful for current brachytherapy measurements.…”
Section: Iiib2 Radiochromic Filmmentioning
confidence: 99%
“…Advantages of EBT film compared to silver halide film include the following: relative energy insensitivity, insensitivity to visible light, selfdeveloping characteristics, greater tissue equivalency, and dose-rate independence. [20][21][22][23] Different investigators have noted up to 15% variation in the film response throughout a film that was exposed to a uniform dose of radiation. Sources for these uncertainties have been pointed out by Bouchard et al 24 Looking at two orthogonal directions, the film response is more uniform in one direction.…”
Section: Iiib2 Radiochromic Filmmentioning
confidence: 99%
“…For improvement of the system sensitivity of radiochromic film dosimetry, the peak wavelength of a scanner light source was tuned to the absorption peak of the radiochromic film [23][24][25][26]. Ranade et al [27] developed a 2D optical film scanner equipped with a red light-emitting diode suitable for the radiochromic film absorption peak.…”
Section: Introductionmentioning
confidence: 99%