2014
DOI: 10.1055/s-0034-1377519
|View full text |Cite
|
Sign up to set email alerts
|

A target-controlled infusion system with bispectral index monitoring of propofol sedation during endoscopic submucosal dissection

Abstract: Background and study aims: Propofol administration via a target-controlled infusion system with bispectral index monitoring (BIS/TCI system) is expected to prevent complications from sedation during complex and long endoscopic procedures. We evaluated the feasibility of setting the BIS/TCI system for non-anesthesiologist administration of propofol (NAAP) during endoscopic submucosal dissection (ESD). Patients and methods: From May 2009 to February 2013, 250 patients with esophagogastric neoplasms were treated … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
2
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 31 publications
0
11
0
Order By: Relevance
“…Although both RSS levels 3-5 (used in the MDZ group) and BIS 60-80 are equivalent to moderate or deep sedation, there are no reports that they are equal. 11,25 BIS monitoring leads to higher patient and endoscopist satisfaction scores; thus, less adverse events in the DEX group might have been affected by BIS monitoring. 26 Finally, the criterion additional sedatives and analgesic differs between the MDZ and the DEX groups.…”
Section: Discussionmentioning
confidence: 99%
“…Although both RSS levels 3-5 (used in the MDZ group) and BIS 60-80 are equivalent to moderate or deep sedation, there are no reports that they are equal. 11,25 BIS monitoring leads to higher patient and endoscopist satisfaction scores; thus, less adverse events in the DEX group might have been affected by BIS monitoring. 26 Finally, the criterion additional sedatives and analgesic differs between the MDZ and the DEX groups.…”
Section: Discussionmentioning
confidence: 99%
“…Although deep sedation in general endoscopic treatment has been reported, data are limited on the monitoring of propofol infusion in older patients [8,9]. This report evaluated the efficacy of the TCI system for propofol sedation during ERCP in different age period elder patients.…”
Section: Discussionmentioning
confidence: 99%
“…Propofol was administered intravenously by using the Diprifusor system which is a TCI system using the pharmacokinetic kinetic parameter set according to the Marsh model. The initial setting of the target blood concentration of propofol (1% Diprivan Injection-kit; AstraZeneca) was set at 2.0μg/mL for the nonelderly patients <70 years old) [7].The initial setting for the elderly patients (>70 years old) was 1.0μg/mL, which was chosen for moderate sedation based on a previous study [8] .The blood concentration of propofol at each time point was calculated automatically and shown on the monitor of the TCI pump. For the objective measurement of the level of consciousness in sedated patients, the A2000 BIS monitor (Aspect Medical Systems, Newton, Mass) was used.…”
Section: B Medication and Monitoringmentioning
confidence: 99%
“…Propofol was administered intravenously by using the Diprifusor system which is a TCI system using the pharmacokinetic kinetic parameter set according to the Marsh model. The initial setting of the target blood concentration of propofol (1% Diprivan Injection-kit; AstraZeneca) was set at 2.0μg/mL for the nonelderly patients<70 years old).The initial setting for the elderly patients (>70 years old) was 1.0μg/mL, which was chosen for moderate sedation [7]. The blood concentration of propofol at each time point was calculated automatically and shown on the monitor of the TCI pump.…”
Section: Medication and Monitoringmentioning
confidence: 99%
“…Bispectral index (BIS) monitoring is an electroencephalography based method that quantifies the depth of anesthesia by analyzing the electroencephalogram and uses a complex algorithm to generate an index score, providing an objective measurement of the level of consciousness in sedated patients [6]. Recently, the utility of the combination of a TCI pump and BIS monitoring system (TCI/BIS system) for endoscopic treatment was reported [7].…”
Section: Introductionmentioning
confidence: 99%