2020
DOI: 10.3390/ijerph17155404
|View full text |Cite
|
Sign up to set email alerts
|

A Systems Approach to Assess Transport and Diffusion of Hazardous Airborne Particles in a Large Surgical Suite: Potential Impacts on Viral Airborne Transmission

Abstract: Airborne transmission of viruses, such as the coronavirus 2 (SARS-CoV-2), in hospital systems are under debate: it has been shown that transmission of SARS-CoV-2 virus goes beyond droplet dynamics that is limited to 1 to 2 m, but it is unclear if the airborne viral load is significant enough to ensure transmission of the disease. Surgical smoke can act as a carrier for tissue particles, viruses, and bacteria. To quantify airborne transmission from a physical point of view, we consider surgical smoke produced b… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 47 publications
0
6
0
Order By: Relevance
“…Large particulate matter is believed to settle within 2 meters of its source. 8 , 11 To understand how long particulate matter remains airborne in a closed room, an air quality detector (model BR-8C) was used to measure the level of indoor PM 2.5 and PM 10 of Bakhour smoke (Arabian incense) over time. A small natural Bakhour woodchip was burnt for 1 min in charcoal.…”
Section: Particulate Matter Dynamicsmentioning
confidence: 99%
“…Large particulate matter is believed to settle within 2 meters of its source. 8 , 11 To understand how long particulate matter remains airborne in a closed room, an air quality detector (model BR-8C) was used to measure the level of indoor PM 2.5 and PM 10 of Bakhour smoke (Arabian incense) over time. A small natural Bakhour woodchip was burnt for 1 min in charcoal.…”
Section: Particulate Matter Dynamicsmentioning
confidence: 99%
“…In Figures 1-4, we add the status of the procedural activity (top) to put in context and explain the bottom graph that displays a real-time measurement of particle count with an off-the-shelf device Dylos DC 1700, Dylos Corp (Riverside, CA, USA), which was used extensively in our air quality study of surgical suites [17]. Following the work of Setti et al, we assume that airborne diffusion of infected droplets from person to person can occur at a distance greater than two meters [32].…”
Section: Key Observationsmentioning
confidence: 99%
“…We specifically developed mathematical and cyber-physical tools to address some of the workflow issues via simulation calibrated on unbiased, real-time, autonomous measurement of clinic performances [13][14][15][16][17][18].…”
mentioning
confidence: 99%
See 2 more Smart Citations