1988
DOI: 10.1016/0020-7101(88)90082-7
|View full text |Cite
|
Sign up to set email alerts
|

A system for the automated data-acquisition of fast transient signals in excitable membranes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1992
1992
2011
2011

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 21 publications
0
3
0
Order By: Relevance
“…NE currents and potentials were measured, respectively, under the voltageand zero-current clamp modes of the EPC-7 (see reference 1). Analogue signals were filtered at 1 kHz and amplified (CyberAmp Programmable Signal Conditioner equipped with an 8pole Bessel filter, Axon Instruments, Foster City, CA) prior to digitization and storage by a fast data acquisition system (51). The signals were monitored on the screen of a standard oscilloscope (2225; Tektronix, Beaverton, OR) and stored on magnetic video tape (VR-10; Instrutech Corp., Elmont, NY) for off-line analysis.…”
Section: Patch-clampmentioning
confidence: 99%
See 1 more Smart Citation
“…NE currents and potentials were measured, respectively, under the voltageand zero-current clamp modes of the EPC-7 (see reference 1). Analogue signals were filtered at 1 kHz and amplified (CyberAmp Programmable Signal Conditioner equipped with an 8pole Bessel filter, Axon Instruments, Foster City, CA) prior to digitization and storage by a fast data acquisition system (51). The signals were monitored on the screen of a standard oscilloscope (2225; Tektronix, Beaverton, OR) and stored on magnetic video tape (VR-10; Instrutech Corp., Elmont, NY) for off-line analysis.…”
Section: Patch-clampmentioning
confidence: 99%
“…The signals were monitored on the screen of a standard oscilloscope (2225; Tektronix, Beaverton, OR) and stored on magnetic video tape (VR-10; Instrutech Corp., Elmont, NY) for off-line analysis. NIC activity was analyzed with custom (51 ) and commercial software (pClamp, Axon). The records shown in the figures were filtered at 100 Hz (pClamp).…”
Section: Patch-clampmentioning
confidence: 99%
“…It also takes advance of the author's experience in the design and construction of electrophysiological electronics since 1977 (Bustamante and McDonald 1983;Bustamante 1988). A great deal of hindsight, based on discussions with colleagues and on comments from anonymous referees of my published and unpublished manuscripts has helped to shape the organization and content of this paper.…”
Section: Brief Historymentioning