2001
DOI: 10.1154/1.1365124
|View full text |Cite
|
Sign up to set email alerts
|

A synchrotron X-ray diffraction study of a small congruent LiNbO3crystal: A compatible approach to powder diffraction

Abstract: Single-crystal synchrotron X-ray diffraction (XRD) data were collected and refined for congruent lithium niobate crystals 8 and 6 μm in diameter, sizes that are comparable to the size of the powder particles used in powder diffraction. The motivation for using such small crystals is to minimize problems such as extinction, which decrease with crystal size. The R/wR factors were 0.011/0.014 and 0.019/0.018, for the 8 and 6 μm data, respectively, and the goodness of fit factors were 2.3(1) and 1.63(8), which com… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
3
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 35 publications
(48 reference statements)
1
3
0
Order By: Relevance
“…Abrahams & Marsh, 1986). Furthermore, our reconstructed difference ED is comparable to those reported by Etschmann & Ishizawa (2001) and Hsu et al (1997), although our data are characterized by fewer artifacts and less blurring. This could, however, mainly be due to the applied MEM approach, which better estimates non-measured reflections (structure factors) with their statistically most likely values (Coppens, 1997).…”
Section: Tablesupporting
confidence: 82%
See 3 more Smart Citations
“…Abrahams & Marsh, 1986). Furthermore, our reconstructed difference ED is comparable to those reported by Etschmann & Ishizawa (2001) and Hsu et al (1997), although our data are characterized by fewer artifacts and less blurring. This could, however, mainly be due to the applied MEM approach, which better estimates non-measured reflections (structure factors) with their statistically most likely values (Coppens, 1997).…”
Section: Tablesupporting
confidence: 82%
“…We compare the refined structure parameters and reconstructed EDs of three differently prepared crystals, of which two were prepared by FIB and one was a manually cut crystal. We discuss the results with respect to reference data from spherical crystals and synchrotron data that have already been published (Etschmann & Ishizawa, 2001;Abrahams & Marsh, 1986;Hsu et al, 1997;Iyi et al, 1992).…”
Section: Introductionmentioning
confidence: 89%
See 2 more Smart Citations