2013
DOI: 10.1109/tbcas.2012.2226719
|View full text |Cite
|
Sign up to set email alerts
|

A Switched-Capacitor Front-End for Velocity-Selective ENG Recording

Abstract: Multi-electrode cuffs (MECs) have been proposed as a means for extracting additional information about the velocity and direction of nerve signals from multi-electrode recordings. This paper discusses certain aspects of the implementation of a system for velocity selective recording (VSR) where multiple neural signals are matched and summed to identify excited axon populations in terms of velocity. The approach outlined in the paper involves the replacement of the digital signal processing stages of a standard… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2018
2018

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 24 publications
(32 reference statements)
0
6
0
Order By: Relevance
“…Zariffa proposed to localize active pathways in peripheral nerves using the sLORETA method (Zariffa et al, 2009} while Wodlinger used a beamforming approach for the same task (Wodlinger and Durand, 2009). Rieger et al tried to increase the information rate by using a MCC associated with velocity-selective recordings (VSR) (Rieger et al, 2004, Rieger andTaylor, 2013). In VSR, a series of ring electrodes are positioned in the longitudinal direction of the nerve.…”
Section: Vn Activity Monitoringmentioning
confidence: 99%
“…Zariffa proposed to localize active pathways in peripheral nerves using the sLORETA method (Zariffa et al, 2009} while Wodlinger used a beamforming approach for the same task (Wodlinger and Durand, 2009). Rieger et al tried to increase the information rate by using a MCC associated with velocity-selective recordings (VSR) (Rieger et al, 2004, Rieger andTaylor, 2013). In VSR, a series of ring electrodes are positioned in the longitudinal direction of the nerve.…”
Section: Vn Activity Monitoringmentioning
confidence: 99%
“…can be implemented in a DSP processor, FPGA or PC (digital beamforming). Analog delays can also replace the digitally implemented delays [21]. In our view, velocity selective beamforming can play an important role both in neuroscience research as well as in clinical investigations.…”
Section: Discussionmentioning
confidence: 99%
“…Also (5) implies that the number of sample points in a given velocity band decreases with increasing velocity. This has been referred to as velocity resolution in the current literature [21].…”
Section: Beampatternmentioning
confidence: 99%
See 1 more Smart Citation
“…Researchers have used nerve cuffs to identify touch force and slip , estimate joint angle (Chan, Lin et al 2012), and as a sensor in closed loop functional electrical stimulation (FES) systems (Haugland and Sinkjaer 1995, Haugland, Lickel et al 1999, Inmann and Haugland 2004. While many researchers have shown it is possible to classify multiple concurrent signals based on the type of sensory information (Raspopovic, Carpaneto et al 2010, Rieger and Taylor 2013, Al-Shueli, Clarke et al 2014, Karimi and Seydnejad 2015, it has not been possible to differentiate more than two concurrent signals of the same type (Raspopovic, Carpaneto et al 2010, Zariffa 2015, which is a major barrier to their use in prosthetic limbs.…”
Section: Introductionmentioning
confidence: 99%