A survey of more than 90 commercially available luminometers and imaging devices for low‐light measurements of chemiluminescence and bioluminescence, including instruments for manual, automatic and specialized operation, for HPLC, LC, GLC and microtitre plates. Part 1: Descriptions

Abstract: This survey was compiled in January and February 1992 from information available in public domain literature requested by and supplied to the author by numerous companies in the previous two months. More than 90 luminometers (manual, automatic, microtitre plate, HPLC, LC, GLC, imaging and specials) from more than 60 companies are included. Each company was invited to supply company brochures, technical details, user manual and information about software and any other information concerning their product(s). Th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
22
0

Year Published

1995
1995
2008
2008

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 68 publications
(22 citation statements)
references
References 7 publications
0
22
0
Order By: Relevance
“…Therefore an extremely sensitive light detector device, such as photomultiplier tubes (Electron Tubes, Ruislip, U.K.) or photon-counting cameras (Scienceware, Pequannock, N.J., U.S.A.; Photek, St. Leonardson-Sea, U.K.; Berthold Detection Systems, Pforzheim, Federal Republic of Germany; Hamamatsu Photonics) (Creton et al 1999;Aikens 1999;Stanley 1992Stanley , 1999, is needed. The spectral properties of the bioluminescent material have to be in accordance with the spectral sensitivity of the detector and photon-counting mode should be used in order to maximize the signalto-noise ratio Wright 1999, Tomkins andLyons 1999).…”
Section: Luminescence Detectorsmentioning
confidence: 99%
“…Therefore an extremely sensitive light detector device, such as photomultiplier tubes (Electron Tubes, Ruislip, U.K.) or photon-counting cameras (Scienceware, Pequannock, N.J., U.S.A.; Photek, St. Leonardson-Sea, U.K.; Berthold Detection Systems, Pforzheim, Federal Republic of Germany; Hamamatsu Photonics) (Creton et al 1999;Aikens 1999;Stanley 1992Stanley , 1999, is needed. The spectral properties of the bioluminescent material have to be in accordance with the spectral sensitivity of the detector and photon-counting mode should be used in order to maximize the signalto-noise ratio Wright 1999, Tomkins andLyons 1999).…”
Section: Luminescence Detectorsmentioning
confidence: 99%
“…The simplest system is that in which the output is directed to a chart recorder, and changes in luminescence are plotted during the experiment. A wide range of models of off-the-shelf chemiluminometers is available [15] or they can be assembled from the component parts, such as those available from Thorn EM!. If choosing a photomultiplier tube, it should be selected for maximum efficiency in the blue light wavelength range, it should have a low dark current (i.e.…”
Section: Experimental Designmentioning
confidence: 99%
“…For the analysis of myocardial ATP, a left ventricular specimen from the risk area was isolated, frozen in the liquid nitrogen and processed for the analysis of ATP levels as described earlier (Stanley, 1992). In brief, the frozen samples were crushed and the cells lysed using Tris hydrochloride and EDTA buffer, pH 7.4.…”
Section: Myocardial Atp Levelsmentioning