2017 14th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technolo 2017
DOI: 10.1109/ecticon.2017.8096342
|View full text |Cite
|
Sign up to set email alerts
|

A survey of hybrid energy storage systems applied for intermittent renewable energy systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 34 publications
(12 citation statements)
references
References 5 publications
0
9
0
Order By: Relevance
“…In addition, a comparative study is performed to demonstrate that an MG with HESS exhibits a better performance than the battery storage system. Reference [41] presents a comparative study on HESS applied to a power system integrated with RES. Reference [42] proposes a model predictive control scheme for an HESS to decrease the charging rate of batteries and maintain the current and voltage of the ultra-capacitor, thus increasing the lifetime of the battery.…”
Section: B Reliability Improvement At Subsystem Levelmentioning
confidence: 99%
“…In addition, a comparative study is performed to demonstrate that an MG with HESS exhibits a better performance than the battery storage system. Reference [41] presents a comparative study on HESS applied to a power system integrated with RES. Reference [42] proposes a model predictive control scheme for an HESS to decrease the charging rate of batteries and maintain the current and voltage of the ultra-capacitor, thus increasing the lifetime of the battery.…”
Section: B Reliability Improvement At Subsystem Levelmentioning
confidence: 99%
“…To account for the impact of high penetrations of ES applications, the load profile changes established in Munson's research was applied to the typical profile [4]. These profile augmentations align with changes produced by hybrid PV and ES systems that are utilized to improve grid stability and customer participation [21][22][23][24]. Utilizing time-of-use practices by utility companies such as Pacific Gas & Electric in California that incentivize customers to charge during the period between 11pm and 7am, the impact of EV charging was applied to the typical load profile [25].…”
Section: Historical Profile Vs Flattened Profilementioning
confidence: 99%
“…Coordination control regarding energy storage devices has been widely developed in solving wind power problems including smoothing the output active power of wind farms, suppressing the shafting oscillation of the DFIG, and assisting the DFIG to realize low-voltage ride through [16,17]. It also provides a new idea for coordinating the DFIG and energy storage to participate in frequency regulation.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, if relying only on an energy storage device or rotor kinetic energy to participate in frequency regulation, it cannot meet the power grid's requirements for a DFIG that simultaneously has a frequency regulation ability and maximum economic benefit. Coordination control regarding energy storage devices has been widely developed in solving wind power problems including smoothing the output active power of wind farms, suppressing the shafting oscillation of the DFIG, and assisting the DFIG to realize low-voltage ride through [16,17]. It also provides a new idea for coordinating the DFIG and energy storage to participate in frequency regulation.…”
Section: Introductionmentioning
confidence: 99%