2014
DOI: 10.1016/j.jtice.2014.02.001
|View full text |Cite
|
Sign up to set email alerts
|

A study on the inhibition of N80 steel in 3.5% NaCl solution saturated with CO2 by fruit extract of Gingko biloba

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
23
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 52 publications
(23 citation statements)
references
References 36 publications
0
23
0
Order By: Relevance
“…It is widely reported that organic inhibitors adsorb on substrate surface to protect against corrosion 43,44 . This adsorption process is a quasi-replacement of adsorbed H 2 O molecules (nH 2 O (ads) ) by inhibitor molecules in aqueous solution (Inh (sol) ) 43,46 :…”
Section: Resultsmentioning
confidence: 99%
“…It is widely reported that organic inhibitors adsorb on substrate surface to protect against corrosion 43,44 . This adsorption process is a quasi-replacement of adsorbed H 2 O molecules (nH 2 O (ads) ) by inhibitor molecules in aqueous solution (Inh (sol) ) 43,46 :…”
Section: Resultsmentioning
confidence: 99%
“…Impedance spectra for J55 and N80 steel in 3.5% NaCl solution saturated with CO 2 in the absence and presence of different concentrations of PM are shown in Fig. 3a–d in the form of Nyquist plots and Bode phase angle plots 31 . The Nyquist plots consist of depressed semicircles with one capacitive loop in the high frequency (HF) zone and one inductive loop in the lower frequency (LF) zone.…”
Section: Resultsmentioning
confidence: 99%
“…As the tip approaches the surface of the N80 steel in the porphyrin containing aggressive solutions, the diffusion field surrounding the tip is hindered and the tip current decreases (Figure 7). This behaviour is typical of an insulating surface and confirmed that the steel surface is covered with protective film in the presence of the inhibitors [38]. In the absence of the porphyrin inhibitors, the tip current increases as the tip was made to approach the surface indicating that the N80 steel surface in the blank 3.5% NaCl solution is conductive and prone to a faster corrosion process.…”
Section: Resultsmentioning
confidence: 55%
“…Prior to each SECM experiment, the distance between the tip and the sample was established by approach curve measurement performed above the insulating part of the sample at −0.70 V. The status of corroded sample was studied by monitoring the probe (tip potential: 0.5 V vs. Ag/AgCl, saturated KCl) and the substrate (tip potential: −0.7 V) in test solutions. Similar approach has been successfully applied and reported elsewhere [38].…”
Section: Resultsmentioning
confidence: 98%