2021
DOI: 10.3390/chemosensors9060129
|View full text |Cite
|
Sign up to set email alerts
|

A Study on the Combination of Enzyme Stabilizers and Low Temperatures in the Long-Term Storage of Glutamate Biosensor

Abstract: The importance of physiological glutamate has been widely demonstrated in cognitive and memory processes, as well as in neurotransmission. The involvement of physiological glutamate in several pathologies has also been established. Therefore, analytical devices for studying variations in physiological glutamate are of fundamental importance, particularly in preclinical studies. The necessary knowledge to develop and characterize biosensors for glutamate detection is often restricted to only a few research grou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 36 publications
(104 reference statements)
0
6
0
Order By: Relevance
“…Based on the particular characteristics highlighted on both polyZING and polyZING DIM ( Figure 10 ), related to good AA shielding and increased HP monitoring, glutamate biosensors were built using the polymers mentioned above and compared with the previously described PPD-based glutamate biosensors [ 13 , 14 , 53 ]: actually, PPD is the most commonly used polymer for amperometric biosensors because of its peculiarities [ 2 , 20 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…Based on the particular characteristics highlighted on both polyZING and polyZING DIM ( Figure 10 ), related to good AA shielding and increased HP monitoring, glutamate biosensors were built using the polymers mentioned above and compared with the previously described PPD-based glutamate biosensors [ 13 , 14 , 53 ]: actually, PPD is the most commonly used polymer for amperometric biosensors because of its peculiarities [ 2 , 20 ].…”
Section: Resultsmentioning
confidence: 99%
“…As previously reported [ 13 , 14 , 53 ], PPD-based biosensors (n = 4) were constructed. In brief, at day 0, a PPD polymer was obtained on a 1 mm cylinder of Pt/Ir, from a 330 mM solution of OPD, previously degassed for 15 min with pure N 2 , and by applying +0.7 V for 30 min.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…62 To extend the storage stability of enzymes and immunosensors, biosensors must be kept with a stabilizer and buffer at a low temperature. 63,64 Also, soil and water quality assessments usually cover a few sampling spots to prevent bias in the measurement results. Hence, a reusable biosensor with high repeatability would be appreciated for multiple measurements at specific spots to reduce cost.…”
Section: Application Of Biosensors In Smart Farmingmentioning
confidence: 99%