2003
DOI: 10.1093/oxfordjournals.rpd.a006149
|View full text |Cite
|
Sign up to set email alerts
|

A study on radiographic repeat rate data of several hospitals in Jeddah

Abstract: Radiographic repeat rate data in diagnostic radiology in King Fahad Hospital (KFH), King Abdulaziz Hospital (KAH), and Maternity and Children Hospital (MCH) in Jeddah, Saudi Arabia, have been studied. The study provided valuable information to suggest preventive measures to reduce repeats. The variables included in the study are exposure techniques, examination types, total number of films used, number of films repeated, the film sizes, gender, the age groups of the patients, and reason for repetition. The tot… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
10
0
5

Year Published

2010
2010
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(16 citation statements)
references
References 0 publications
1
10
0
5
Order By: Relevance
“…The radiographers were informed about the study through a series of presentations. The forms included the following information: type of examination, number and size of film used, number and size of film repeated, reason for repetition, gender and age group (infant (0 -5 years), child (5 -14 years), adult (14 years and above)) [4].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The radiographers were informed about the study through a series of presentations. The forms included the following information: type of examination, number and size of film used, number and size of film repeated, reason for repetition, gender and age group (infant (0 -5 years), child (5 -14 years), adult (14 years and above)) [4].…”
Section: Methodsmentioning
confidence: 99%
“…The use of ionizing radiation in medical imaging contributes the largest amount of man-made exposure to the public [3]. It has been estimated that about 21% of the total somatic dose and about 10% of the total genetically significant dose arise from medical procedures, the most important contributor being diagnostic radiology [4]. Diagnostic procedures contribute more than 95% of the medical exposures [5].…”
Section: Introductionmentioning
confidence: 99%
“…A review of the literature revealed that repeated image rates hovered around 10% in screen-film departments, with approximately 45% of images repeated owing to exposure errors, which are expected to be greatly reduced in digital imaging. 9,11,12,23,[25][26][27] Rejected image rates in digital departments have been reported to range from 4% to 8%. [10][11][12]14,16 Therefore, this task group recommends that 8% be used as a target for overall rejected image rate, and 10% as a threshold for investigation and possible corrective action.…”
Section: B4 Corrective Actionmentioning
confidence: 99%
“…Assi: Rate of repeating X-rays methodology was used [8]. The rejected films were those labeled as useless, or discarded radiographs.…”
Section: Methodsmentioning
confidence: 99%
“…For this study, repeated film is defined as an x-ray film that is repeated for diagnostic purposes due to the inadequacy of the initial imaging study. Clearly, this will result in additional exposure to radiation by the patient [8]. Therefore, optimizing X-ray imaging in order to reduce the likelihood of repeated imaging and patient exposure to extra radiation is an important and complex process given the high standards required for obtaining a meaningful and informative X-ray with a good quality to assist in the diagnostic process [9].…”
Section: Introductionmentioning
confidence: 99%