1971
DOI: 10.1017/s0022112071001241
|View full text |Cite
|
Sign up to set email alerts
|

A study of the constant-temperature hot-wire anemometer

Abstract: The conventional ‘bridge-feedback amplifier’ constant-temperature hot-wire anemometer is analysed to determine its static and dynamic response. The effects of moderate feedback amplifier gain, bridge imbalance, stray bridge reactance, amplifier offset voltage, lack of common mode rejection, amplifier frequency response and departure from constant transconducture are included. The root loci of the system are mapped out and the consequences of the analysis are discussed from the viewpoint of both the operator an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
43
0
1

Year Published

1981
1981
2014
2014

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 89 publications
(44 citation statements)
references
References 2 publications
0
43
0
1
Order By: Relevance
“…Details of the anemometer design are given in Perry 27 and Perry and Morrison. 28 The single-normal hot-wire probe used is a boundary layer type probe-body geometry 55P15 from Dantec, while the cross-wire probe is 55P61 from the same manufacturer. Both probe sensors consist of 5 µm diameter platinum filament sensors, formed from Wollaston wire with an etched length l = 1 mm.…”
Section: Velocity Measurementsmentioning
confidence: 99%
“…Details of the anemometer design are given in Perry 27 and Perry and Morrison. 28 The single-normal hot-wire probe used is a boundary layer type probe-body geometry 55P15 from Dantec, while the cross-wire probe is 55P61 from the same manufacturer. Both probe sensors consist of 5 µm diameter platinum filament sensors, formed from Wollaston wire with an etched length l = 1 mm.…”
Section: Velocity Measurementsmentioning
confidence: 99%
“…De acordo com Davis (1970); Perry & Morrison (1971); Weidman & Browand (1975); Ower & Pankhurst (1977); Lomas (1986) ;Miller et al (1987); Pearcy et al (1989); Watmuff (1995) o anemômetro de fio quente de temperatura constante caracterizase pelo aquecimento do sensor por determinada corrente elétrica, seu resfriamento devido às trocas de calor com o fluido e mantença da resistência e temperatura média do sensor a valores praticamente constantes, por um sistema de realimentação, que fornece a corrente elétrica de aquecimento, variável com a velocidade do fluido (Figura 5).…”
Section: Figura 3 Ponte De Wheatstoneunclassified
“…This makes the hot-wire anemometer particularly attractive for high-frequency turbulence measurements. Dynamic analysis of the CTA Bridge has been attempted by several authors (in particular Freymuth (1967Freymuth ( , 1977 and Perry and Morrison (1971)) with varying degrees of success. Apart from the complex thermal and electrical interactions within the bridge; the system is inherently non-linear, as highlighted by Freymuth (1979 For any quantitative work, it is essential to calibrate the probes individually.…”
Section: Cta Bridge Operationmentioning
confidence: 99%
“…Weighting factors are included to give a curve-fitting accuracy approximating to a constant percentage of reading.~r Constant-temperature anemometry is a well-established technique for investigating turbulent flow. Although the method is now venerable, detailed points of design still generate controversy (Freymuth, 1967, 19777;Perry and Morrison, 1971). …”
mentioning
confidence: 99%