1989
DOI: 10.1016/s0272-6386(89)80151-9
|View full text |Cite
|
Sign up to set email alerts
|

A Study of the Basic Principles Determining the Performance of Several High-Flux Dialyzers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
23
0

Year Published

1992
1992
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 59 publications
(24 citation statements)
references
References 4 publications
1
23
0
Order By: Relevance
“…This probably indicates adsorption of P2M onto the polyester-polymer alloy membrane from the begin ning of the session, a pattern not seen with the three other dialyzers. The first hour adsorption of P2M onto the polyester-polymer alloy membrane has also been shown by Stein et al [1], The adsorption of P2M seems to differ for the various types of membrane depending on their degree of hydrophobicity [14], Among the same dialyzers the surface area also seems to play a role [15]. From our study we can speculate that P2M adsorption onto the dial ysis membranes we studied is relatively high during the first hours of the session in polyester-polymer alloy mem brane, stable and rather small in cellulose diacetate and small during the first hour of the session in polysulfone and polyacrylonitrile membranes.…”
Section: Discussionmentioning
confidence: 75%
“…This probably indicates adsorption of P2M onto the polyester-polymer alloy membrane from the begin ning of the session, a pattern not seen with the three other dialyzers. The first hour adsorption of P2M onto the polyester-polymer alloy membrane has also been shown by Stein et al [1], The adsorption of P2M seems to differ for the various types of membrane depending on their degree of hydrophobicity [14], Among the same dialyzers the surface area also seems to play a role [15]. From our study we can speculate that P2M adsorption onto the dial ysis membranes we studied is relatively high during the first hours of the session in polyester-polymer alloy mem brane, stable and rather small in cellulose diacetate and small during the first hour of the session in polysulfone and polyacrylonitrile membranes.…”
Section: Discussionmentioning
confidence: 75%
“…The in vitro B|2 clearance for the Duofiux was 88 ml/min compared to 34-45 for the conventional dialyzers. The [T-microglobulin clear ance of the Duofiux was 11.4 ml/min [3] compared to no clearance by the conventional membranes. The in vivo ultrafiltration rate was 15 ml/h/mm Hg transmembrane pressure for the Duofiux compared to 3.5-5.0 for the conventional dialyzers.…”
Section: Methodsmentioning
confidence: 89%
“…The high-flux cellulose acetate membrane used had a higher vitamin B12 clearance than the conventional mem brane (88 ml/min vs. 34-45 ml/min) and a much higher P2-microglobulin clearance [3]. While the vitamin B|?…”
Section: Discussionmentioning
confidence: 96%
“…Jindal et al [26] have reported beta-2-microglobulin sieving coefficients of 0.27 for the high flux cellulose acetate dialyzer used in this study compared to 0.47 and 0.43 for polysulfone membranes with ultrafiltration rates of 40 and 60. The beta-2-microglobulin clearance for the high flux cellulose acetate dialyzer was 11.4 compared to 17.3-54 ml/min for high flux polyacrylnitrile and polysulfone dialyzers.…”
Section: Discussionmentioning
confidence: 51%