2007
DOI: 10.5005/jcdp-8-7-29
|View full text |Cite
|
Sign up to set email alerts
|

A Study of Temperature Rise in the Pulp Chamber during Composite Polymerization with Different Light-curing Units

Abstract: Aim:The study compared pulp temperature rise during polymerization of resin-based composites (RBCs) using halogen and LED light-curing units (LCUs). Methods and Materials:A total of 32 teeth extracted from patients aged 11-18 years were used in the study. Thermocouples placed on the roof of the pulp chamber using a novel 'split-tooth' method. In Group 1 a halogen LCU with a light intensity of 450 mWcm -2 was used and in Group 2, an LED LCU with a light intensity of 1100 mWcm -2 was used. The teeth were placed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
23
2
3

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 42 publications
(31 citation statements)
references
References 15 publications
2
23
2
3
Order By: Relevance
“…24,25 One or two TCs are commonly placed inside the pulp chamber or the root canal of intact teeth to detect pulp temperature, 25,26 even though several limitations like an unexact positioning of the TCs, the influence of different RDTs on temperature rise, nonreal-time measurements at different positions, and a possible gap between TC and dentine, probably lead to measurement errors. 30,31 Biological variation was minimized by removing the crowns and apices. 28,29 Although these modifications in geometry and mass have an influence on heat conduction 27 and heat capacity, no significant differences in the temperature rise between split teeth and intact teeth have been reported in the literature.…”
Section: Model Developmentmentioning
confidence: 99%
“…24,25 One or two TCs are commonly placed inside the pulp chamber or the root canal of intact teeth to detect pulp temperature, 25,26 even though several limitations like an unexact positioning of the TCs, the influence of different RDTs on temperature rise, nonreal-time measurements at different positions, and a possible gap between TC and dentine, probably lead to measurement errors. 30,31 Biological variation was minimized by removing the crowns and apices. 28,29 Although these modifications in geometry and mass have an influence on heat conduction 27 and heat capacity, no significant differences in the temperature rise between split teeth and intact teeth have been reported in the literature.…”
Section: Model Developmentmentioning
confidence: 99%
“…Thus, the first hypothesis was accepted. In this regard, consistent baseline, plateau temperature values were observed, having a very low standard deviation (±0.7 • C), with a confidence interval ranging from 35.0 to 35.7 • C. In contrast to the assumption that anesthetized human pulp has the same temperature as the human body core (approximately 37 • C) [5,7], lower temperature values (35.3 • C ± 0.7 • ) with a temperature range lower than that observed in the axilla: 36.2 to 37.5 • C [15] were observed within the pulp, after 25 min of stabilization. Thus, the second research hypothesis was rejected.…”
Section: Discussionmentioning
confidence: 54%
“…In that study, a 5.5 • C PT increase in rhesus monkeys, from application of a hot metal source to the facial enamel surface, induced necrosis in 15% of evaluated pulps. Because of the high expense of animal testing, in vitro techniques using extracted teeth were developed to evaluate pulp chamber temperature change under simulated clinical conditions, while applying various external heat sources [5,7,8]. In these reports, the pulp chamber temperature, prior to application of temperature-raising effects, was pre-set at 37 • C (human body temperature) [5,7,9], or at room temperature [4], or was not mentioned in the study [10,11].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Contudo, outros fatores devem ser considerados, tais como o comprimento de onda do equipamento e o tipo de matriz da resina composta. Tendo em vista a complexidade da avaliação da temperatura, outros estudos seriam necessários para complementar as informações obtidas neste trabalho, uma vez que a extensão da lesão térmica que pode ser tolerada pela polpa dentária é desconhecida (BALDISSARA et al, 1997, STEWARDSON et al, 2004MILLEN et al, 2007). De acordo com os resultados obtidos, foi possível concluir que:…”
Section: ____________________________________________________________unclassified