2014
DOI: 10.1016/j.epsr.2014.03.015
|View full text |Cite
|
Sign up to set email alerts
|

A study of human safety against lightning considering the grounding system and the evaluation of the associated parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
7
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 5 publications
3
7
0
Order By: Relevance
“…The touch or contact voltage is calculated by the use of the human body model given in Fig. The corresponding currents passing through the heart are illustrated in Figures 6(a The obtained results are in agreement with those that were reached in reference [21], and the differences are due to the fact that in this article the study was done in the case of two-layer soils and that the ionization state in the soil was considered.…”
Section: A the Impact Of Soil Ionization On The Step And Touch Potent...supporting
confidence: 80%
See 3 more Smart Citations
“…The touch or contact voltage is calculated by the use of the human body model given in Fig. The corresponding currents passing through the heart are illustrated in Figures 6(a The obtained results are in agreement with those that were reached in reference [21], and the differences are due to the fact that in this article the study was done in the case of two-layer soils and that the ionization state in the soil was considered.…”
Section: A the Impact Of Soil Ionization On The Step And Touch Potent...supporting
confidence: 80%
“…Therefore, the modeling process is the only method for conducting such studies. In any case, it is possible to compare the results obtained with that reported by others [21], [31][32][33]; especially those who used the same model of human representation [21]. The contact potentials with negative and positive reflection factors for different wave peaks considering soil ionization are given in Figures 14(a The corresponding currents passing through the heart are illustrated in Figures 15(a By comparing the results obtained in this study with those obtained in a reference, it is found an agreement in the case of touch voltage.…”
Section: The Influence Of the Wave Peaks On The Current Passing Throu...mentioning
confidence: 77%
See 2 more Smart Citations
“…The diameter of flexible graphite composite grounding material is generally between 22mm and 40mm. Larger grounding electrode diameter can increase the effective current dissipation area [7]. However, when using the complete similarity theory to conduct the grounding simulation test of grounding material, the similarity terms of grounding electrode diameter and grounding electrode resistivity cannot be scaled down completely.…”
Section: Introductionmentioning
confidence: 99%