2019 10th International Power Electronics, Drive Systems and Technologies Conference (PEDSTC) 2019
DOI: 10.1109/pedstc.2019.8697853
|View full text |Cite
|
Sign up to set email alerts
|

A Step by Step Design Procedure of PR controller and Capacitor Current Feedback Active Damping for a LCL-Type Grid-tied T-Type Inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(7 citation statements)
references
References 13 publications
0
6
0
Order By: Relevance
“…According to (9), to eliminate the grid current distortion caused by the grid voltage harmonics, a feedforward path from v g (s) is added to the G x1 (s) output, as shown in…”
Section: Grid-voltage-full-feedforward (Gvff)mentioning
confidence: 99%
See 1 more Smart Citation
“…According to (9), to eliminate the grid current distortion caused by the grid voltage harmonics, a feedforward path from v g (s) is added to the G x1 (s) output, as shown in…”
Section: Grid-voltage-full-feedforward (Gvff)mentioning
confidence: 99%
“…Different network interface filters, including L, LC, LCL, and LLCL-filters are utilized. 8,9 Since in an L-type filter, only one inductor is responsible for reducing current harmonics, the inductor size or switching frequency must be high enough to improve the performance, as losses increase in both cases. The LC filter performs better at high frequencies and is smaller than the L filter.…”
Section: Introductionmentioning
confidence: 99%
“…The output impedance of the proposed control scheme, according to Figure 7C, is calculated as Equation (13). A Norton equivalent circuit can be provided to the grid-tied inverter, including an ideal current reference i s (s) in parallel with the output impedance Z o (s).…”
Section: Performance Control and Shaping Of Output Impedancementioning
confidence: 99%
“…The LCL filters are very suitable compared to L and LC filters due to their high ability to dampen the harmonics and their smaller size. [13][14][15] However, the inherent resonance of the LCL filter inflicts some problems in injecting stable and high-quality current into the network. 16 The stability and power quality of the grid-connected inverter are affected when the distributed power generation system (DPGS) is connected to a weak grid with a long radial feeder.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation