2020
DOI: 10.1039/d0ay01565b
|View full text |Cite
|
Sign up to set email alerts
|

A spot test for determination of residual TBA levels in18F-radiotracers for human use using Dragendorff reagent

Abstract: When utilizing [18F]tetrabutylammonium fluoride ([18]TBAF) in the synthesis of 18F-labeled radiotracers for clinical positron emission tomgraphy (PET) imaging, it is necessary to confirm that residual TBA levels in formulated doses...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 28 publications
0
5
0
Order By: Relevance
“…Satisfactory and rapid results were obtained upon immersing the developed plate in Dragendorff's reagent for 30 seconds, with intense orange spots achieved for ALF and SOL. 35,36 This may be attributed to the abundance of nitrogenous groups in the chemical structures of ALF and SOL (Fig. S1A†).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Satisfactory and rapid results were obtained upon immersing the developed plate in Dragendorff's reagent for 30 seconds, with intense orange spots achieved for ALF and SOL. 35,36 This may be attributed to the abundance of nitrogenous groups in the chemical structures of ALF and SOL (Fig. S1A†).…”
Section: Resultsmentioning
confidence: 99%
“…The developed plates were divided into two equal parts along the direction of mobile phase development so that every developed track was adequately tted in the camera's eld of view. Each part was immersed in Dragendorff's reagent 33,35,36 for 30 seconds, rinsed with a small amount of distilled water and le until complete dryness. Aer that, the plates were xed on the bottom lid of the illumination chamber using the paper clip and illuminated under the daylight LED strip.…”
Section: Chromatographic Conditionsmentioning
confidence: 99%
“…Lastly, one of the automated production batches was reformulated into 10% ethanol in saline using a C18 cartridge. We analyzed the formulated product for residual tetramethylammonium salts using recently developed TLC methods . This analysis shows levels below the accepted regulatory limits (not more than 2.6 mg/10 mL patient dose), promising results for translation of this methodology to the production of PET radiotracers for clinical use.…”
Section: Resultsmentioning
confidence: 99%
“…Radio-TLC analyses were performed using a Bioscan AR 2000 Radio-TLC scanner with EMD Millipore TLC silica gel 60 plates (3.0 cm wide × 6.5 cm long). Residual TMA levels were determined using TLC spot tests as previously described . Chromatography was performed using the following conditions.…”
Section: Methodsmentioning
confidence: 99%
“…However, using this oxalate-based eluent resulted in substantial losses through the QMA (66 ± 19% recovery, n = 3). Switching to a solution of TBA-HCO 3 as QMA eluent dramatically improved both the reliability Tanzey et al 2020), giving an official guideline to verify the residual content of TBA-HCO 3 in the final product vial, which is not the case for oxalate-based eluents. Gratifyingly, commercially available carbonated QMA could be used without the need for manual conditioning of the cartridge.…”
Section: Discussionmentioning
confidence: 99%