2017
DOI: 10.1007/s10586-017-1351-0
|View full text |Cite
|
Sign up to set email alerts
|

A spatio-frequency orientational energy based medical image fusion using non-sub sampled contourlet transform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…NSCT is proved to be an effective transformation technique to avoid the pseudo-Gibbs phenomenon, and it can capture the higher dimensional singularities, such as edges and contours, that cannot be effectively represented by the wavelets and contourlet. 14 CLAHE can improve the overall contrast of underwater images and suppress noise amplification compared to other algorithms. 15 The contributions of this paper can be summarized as follows:…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…NSCT is proved to be an effective transformation technique to avoid the pseudo-Gibbs phenomenon, and it can capture the higher dimensional singularities, such as edges and contours, that cannot be effectively represented by the wavelets and contourlet. 14 CLAHE can improve the overall contrast of underwater images and suppress noise amplification compared to other algorithms. 15 The contributions of this paper can be summarized as follows:…”
Section: Introductionmentioning
confidence: 99%
“…To further improve the imaging quality of underwater images, we propose an underwater polarization image fusion method based on NSCT and CLAHE. NSCT is proved to be an effective transformation technique to avoid the pseudo-Gibbs phenomenon, and it can capture the higher dimensional singularities, such as edges and contours, that cannot be effectively represented by the wavelets and contourlet 14 . CLAHE can improve the overall contrast of underwater images and suppress noise amplification compared to other algorithms 15 …”
Section: Introductionmentioning
confidence: 99%
“…According to the National Laboratories WHO scientific guidelines, real-time polymerase chain reaction (RT-PCR) testing is the gold standard for validating the diagnosis of COVID-19. However, the RT-PCR test became inadequate, and showed high levels of false-negative results to confirm cases that were positive for COVID-19 [ 1 5 ]. In addition RT-PCR is a very time-consuming, complex manual process, and kits are currently lacking.…”
Section: Introductionmentioning
confidence: 99%
“…The watermark is integrated into the coefficients obtained by transforms. The wavelet transform of a signal allows representing the signal on a two-dimensional space called the time-scale plane, providing joint information on the signal in time and frequency [ 10 ]. The paving of the time–frequency plane induced by this transforms has the particularity of allowing a fine temporal resolution at high frequencies and a fine frequency resolution at low frequencies [ 11 ].…”
Section: Introductionmentioning
confidence: 99%