“…A standardized measurement protocol (Bassinet et al, 2014a) was applied in this study. This protocol called "OSL with preheat" was developed using OSL of resistors extracted from the circuit board of mobile phones in the framework of the EU-FP7 MULTIBIODOSE project and tested in several interlaboratory comparisons for retrospective dosimetry and field tests in the framework of the EU-FP7 CATO project (Discher et al, 2021), the "European Radiation Dosimetry" (EURADOS) WG 10 and "Running the European Network for Biological Dosimetry and Retrospective Physical Dosimetry" (RENEB) network (Waldner et al, 2021)), the "Korea retrospective dosimetry network" (KREDOS) group (Kim et al, 2022) and, more recently, again the RENEB network (Port et al, 2023). The OSL signals were measured at 100 • C for 30 s after a preheat up to 120 • C for 10 s. The calibration dose was approx.…”