2021 IEEE Energy Conversion Congress and Exposition (ECCE) 2021
DOI: 10.1109/ecce47101.2021.9595014
|View full text |Cite
|
Sign up to set email alerts
|

A Six-Switch Five-Level Transformer-less Inverter without Leakage Current for Grid-Tied PV System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 16 publications
0
6
0
Order By: Relevance
“…The identical capacitors used in the DC links of single-phase MLIs may be used in three-phase systems. Table 7 provides a comparative study of different mid-point-clamped SC-MLIs [187][188][189][190][191][192][193][194][195][196][197]. a.…”
Section: Mid-point-clamped Sc-mlismentioning
confidence: 99%
“…The identical capacitors used in the DC links of single-phase MLIs may be used in three-phase systems. Table 7 provides a comparative study of different mid-point-clamped SC-MLIs [187][188][189][190][191][192][193][194][195][196][197]. a.…”
Section: Mid-point-clamped Sc-mlismentioning
confidence: 99%
“…39(e)-(g) shows three different CGSCbased inverter configurations, which are able to generate 5L double voltage conversion gain output using six power switches [127]- [129], seven power switches [132], [144], and eight power switches [135], respectively. Ardashir et al [145] have recently introduced a 5L CGSC-based inverter, which comprises six power switches. Although it has used a similar virtual dc-link SC technique to create the negative output voltage levels, its overall voltage conversion gain is unity.…”
Section: Cgsc-based Mlismentioning
confidence: 99%
“…Regarding these contributions, many new challenges, design considerations, and practical limitations have been reported. Accordingly, MLIs with the SC concept are developed through different circuit configurations, such as single [19]- [75] and multiple [5], [6], [73], [76]- [91] dc-source structures, mid-point-clamped techniques [92]- [120], and common-grounded (CG)-based topologies [121]- [145]. Their performance is much improved using a hybrid topological design, where other well-known integrated techniques, such as flying-capacitor (FC) [146]- [157] and switchedboost (SB) [158], [159] technologies, are merged with the SC concept.…”
Section: Introductionmentioning
confidence: 99%
“…In this part the proposed inverter is compared with the well-known H5 [11], HERIC [12], Virtual-dc-bus [13], NPC [14], T-type NPC [15], and Flying-Capacitor [16] three-level inverters, from different point of views. All the mentioned inverters are employed in grid-tied PV applications and depicted in Fig.…”
Section: Benchmarking With the Prior-art Pv Invertermentioning
confidence: 99%
“…Although these inverters have successfully caused zero leakage current, they suffer from non-symmetric usage and nonequal power loss of the utilized components. Several common-ground PV inverters are introduced in [15][16][17]. The topological solution for grid-tied transformerless PV inverters are to use neutral point clamped inverters like Neutral point clamped (NPC) and T-type-NPC [18][19][20].…”
Section: Introductionmentioning
confidence: 99%