A Single-Tube Nucleic Acid Extraction, Amplification, and Detection Method Using Aluminum Oxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
13
0
1

Year Published

2008
2008
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 12 publications
(13 reference statements)
0
13
0
1
Order By: Relevance
“…However, the binding of nucleic acids to AAO in the presence of guanidinium appears to be irreversible (21). This phenomenon might be exploited for solid-phase amplifications (20), but for our application it is a possible source of loss.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…However, the binding of nucleic acids to AAO in the presence of guanidinium appears to be irreversible (21). This phenomenon might be exploited for solid-phase amplifications (20), but for our application it is a possible source of loss.…”
Section: Discussionmentioning
confidence: 99%
“…We chose the salting-out extraction procedure, rather than one of the popular guanidinium-based extraction methods, because guanidinium salts have been reported to cause irreversible binding of DNA to AAO (20,21). We later described a modification of our filter-extraction protocol (22) in which extraction buffer is back flushed through the membrane rather than being pushed through in the same direction as the sample.…”
mentioning
confidence: 99%
“…Диагноз генитального герпеса ставился на основании анамнеза заболевания, типичных высыпаний, выявления антигена ВПГ 2 типа в ИФА, в тест-системе «Герпескрин» (Ниармедик плюс, Россия), а также с помощью ПЦР (in house), с использованием праймеров, специфичных для Herpes simplex, тип 2 -5`-GTACAGACCTTCGGAGG-3` и 5`-CGCTTCATCATGGGC-3` [11]. Использовали следующий режим амплификации (40 циклов): 94°C -30 с., 60°С -40 с., 72°С -50 с. на амплификаторе «Терцик» (Россия).…”
Section: Introductionunclassified
“…3,4) This method is rapid and requires few manipulations. Single-tube real-time PCR methods, using an aluminum oxide filter and a heated guanidine solution, have also been attempted.…”
mentioning
confidence: 99%
“…Single-tube real-time PCR methods, using an aluminum oxide filter and a heated guanidine solution, have also been attempted. 3,4) However, these extraction processes required special handling, such as pressure filtration and dry evaporation of samples. In addition, these methods could extract total DNA from a sample but could not specifically isolate target DNA.…”
mentioning
confidence: 99%