38th IAS Annual Meeting on Conference Record of the Industry Applications Conference, 2003.
DOI: 10.1109/ias.2003.1257652
|View full text |Cite
|
Sign up to set email alerts
|

A single phase high frequency AC microgrid with an unified power quality conditioner

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
20
0

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 47 publications
(20 citation statements)
references
References 8 publications
0
20
0
Order By: Relevance
“…The instantaneous p -q theory is expanded from the concept of single phase p-q theory [5], [6], [10], [19] and the corresponding voltage equations are mentioned below in eq. (1), (2) & (3).…”
Section: The Control Strategy For the Series Apf'smentioning
confidence: 99%
See 1 more Smart Citation
“…The instantaneous p -q theory is expanded from the concept of single phase p-q theory [5], [6], [10], [19] and the corresponding voltage equations are mentioned below in eq. (1), (2) & (3).…”
Section: The Control Strategy For the Series Apf'smentioning
confidence: 99%
“…When the system is effecting unbalance of power quality issues, in order to overcome to design of UPQC with new control technique for the improvement of power quality using FLC alone, along with PI controller and its comparison is reported in [2]. When the system is connected to 3P4W, the improvement of power quality issues like a voltage, current unbalance, distortions, reactive power demanded by the load using UPQC is reported in [5] - [10].…”
Section: Introductionmentioning
confidence: 99%
“…Since then, a new language was developed to describe the fuzzy properties of reality, which are very difficult and sometime even impossible to be described using conventional methods. Fuzzy set theory has been widely used in the control area with some application to power system [5]. A simple fuzzy logic control is built up by a group of rules based on the human knowledge of system behavior.…”
Section: Proposed Fuzzy Logic Controllermentioning
confidence: 99%
“…These resultant two phase systems can be represented in α-β coordinates, and thus P-Q theory applied for balanced three phase system [11] can also be used for each phase of unbalanced system independently. In order to eliminate these limitations, the reference load voltage signals extracted for series APF are used instead of actual load voltage [12], [13].…”
Section: B Description Of Implementation Of Shunt Apfmentioning
confidence: 99%