A simultaneous extraction/derivatization strategy coupled with liquid chromatography–tandem mass spectrometry for the determination of free catecholamines in biological fluids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
5
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 33 publications
(6 citation statements)
references
References 30 publications
0
5
0
1
Order By: Relevance
“…Индивидуальные исходные растворы (stock solution, 1 мг/мл) моноаминовых НТ готовили на метаноле (J.T. Backer, Польша) путём растворения в мерных колбах объёмом 50 мл 50 мг субстанции каждого аналита в пересчёте на основание [15]. Использовали аналитические стандарты Sigma Aldrich: серотонина гидрохлорид (CAS: 153-98-0), норэпинефрина гидрохлорид (CAS: 55-27-6), эпинефрина гидрохлорид (CAS: 329-63-5), дофамина гидрохлорид (CAS: 62-31-7), гистамин (CAS: 51-45-6), в качестве внутреннего стандарта (IS) применяли сальбутамол (CAS: 18559-94-9).…”
Section: материалы и методы / Materials and Methodsunclassified
“…Индивидуальные исходные растворы (stock solution, 1 мг/мл) моноаминовых НТ готовили на метаноле (J.T. Backer, Польша) путём растворения в мерных колбах объёмом 50 мл 50 мг субстанции каждого аналита в пересчёте на основание [15]. Использовали аналитические стандарты Sigma Aldrich: серотонина гидрохлорид (CAS: 153-98-0), норэпинефрина гидрохлорид (CAS: 55-27-6), эпинефрина гидрохлорид (CAS: 329-63-5), дофамина гидрохлорид (CAS: 62-31-7), гистамин (CAS: 51-45-6), в качестве внутреннего стандарта (IS) применяли сальбутамол (CAS: 18559-94-9).…”
Section: материалы и методы / Materials and Methodsunclassified
“…Among them, the electrochemical sensor has the advantages of good portability, strong operability, short response time, low cost, low detection limits, and high sensitivity, and has been widely applied to detect and continuously monitor various metabolites in body biofluids. 24,25 Therefore, it was considered to construct an electrochemical sensor for the simultaneous detection of three substances. It has been shown that the electrochemical REDOX peak of a substance can be used for its specific identification when an electrochemical sensor is used to detect the substance.…”
Section: Introductionmentioning
confidence: 99%
“…HPLC methods are more preferable than GC because biogenic amines are low volatile and have the functional groups to be derivatized for spectrophotometric detections. The application of derivatization in chromatography is the subject of many studies [ 21 , 22 , 23 ]. This process consists of converting the analytes into appropriate derivatives with properties enabling their chromatographic separation.…”
Section: Introductionmentioning