2019
DOI: 10.1002/acm2.12698
|View full text |Cite
|
Sign up to set email alerts
|

A simulation‐based method for evaluating geometric tests of a linac c‐arm in quality control in radiotherapy

Abstract: Purpose Assessment of the accuracy of geometric tests of a linac used in external beam therapy is crucial for ensuring precise dose delivery. In this paper, a new simulation‐based method for assessing accuracy of such geometric tests is proposed and evaluated on a set of testing procedures. Methods Linac geometry testing methods used in this study are based on an established design of a two‐module phantom. Electronic portal imaging device (EPID) images of fiducial balls contained in these modules can be used t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3
1

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 13 publications
0
2
0
Order By: Relevance
“…To systematically evaluate the contribution of errors which affect the quality of delivery of a radiotherapy plan, QA procedures are usually applied at three consecutive levels: a level to address the geometry and performance of the medical accelerator with its accessories [1][2][3][4] -as controlled by the TPS, and the performance of the TPS itself, 5 a level to address individual patient issues prior to acceptance of a dose delivery plan, [5][6][7] and finally one to address the actual course of radiotherapy (such as patient set-up, or inter-and intrafraction patient positioning and anatomy changes).…”
Section: Introductionmentioning
confidence: 99%
“…To systematically evaluate the contribution of errors which affect the quality of delivery of a radiotherapy plan, QA procedures are usually applied at three consecutive levels: a level to address the geometry and performance of the medical accelerator with its accessories [1][2][3][4] -as controlled by the TPS, and the performance of the TPS itself, 5 a level to address individual patient issues prior to acceptance of a dose delivery plan, [5][6][7] and finally one to address the actual course of radiotherapy (such as patient set-up, or inter-and intrafraction patient positioning and anatomy changes).…”
Section: Introductionmentioning
confidence: 99%
“…Advances in radiotherapy are reflected in increasingly complex tests of commissioning, therapy planning, onboard imaging, beam geometry, or beam delivery systems [1][2][3][4][5], and of dosimetry tools [6]. Among such tests, patientspecific procedures [1,2,7,8] remain the core component of clinical quality assurance (QA).…”
Section: Introductionmentioning
confidence: 99%