2007 European Conference on Power Electronics and Applications 2007
DOI: 10.1109/epe.2007.4417751
|View full text |Cite
|
Sign up to set email alerts
|

A simpler and faster method for SVM implementation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 11 publications
0
2
0
Order By: Relevance
“…In addition, phases b and c apply the same ideas using different coordinates. The next target of this proposed NVC method is to minimize the common-mode voltage, which may result in a better use of the available DC voltage [54][55][56]. The base states given by (50) of the MMC can be modified by means of (54) by using for the three phases the same redundancy value, named ρ [53].…”
Section: Proposed Nvc Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, phases b and c apply the same ideas using different coordinates. The next target of this proposed NVC method is to minimize the common-mode voltage, which may result in a better use of the available DC voltage [54][55][56]. The base states given by (50) of the MMC can be modified by means of (54) by using for the three phases the same redundancy value, named ρ [53].…”
Section: Proposed Nvc Methodsmentioning
confidence: 99%
“…Therefore, in order to reduce the common-mode voltage, the value of ρ given by ( 53) is used to find the minimum average distance of the three phases to the central point given by (Nsm/2, Nsm/2, Nsm/2), constrained by the maximum and minimum values of ρ given by The next target of this proposed NVC method is to minimize the common-mode voltage, which may result in a better use of the available DC voltage [54][55][56]. The base states given by (50) of the MMC can be modified by means of (54) by using for the three phases the same redundancy value, named ρ [53].…”
Section: Proposed Nvc Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Control software variables are transmitted to the PC via serial port interface. The standard SV-PWM voltage modulation method is used [15] at the frequency of 10 kHz.…”
Section: Methodsmentioning
confidence: 99%
“…2). An exemplary sequence of transistor control signals in a modulation period using Space Vector method (SV-PWM) [15] is presented in Fig. 3.…”
Section: Current Sampling Algorithmsmentioning
confidence: 99%