2008
DOI: 10.1109/tie.2008.917066
|View full text |Cite
|
Sign up to set email alerts
|

A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an $LCL$ Filter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
112
0
1

Year Published

2016
2016
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 258 publications
(113 citation statements)
references
References 17 publications
0
112
0
1
Order By: Relevance
“…According to the equivalent circuit of the proposed impedance-matching based control, the reconstructed output impedance of the GCC can be obtained in (10). Comparing the original output impedance in (4) with the conventional double-loop control scheme, the zero and pole placement of the output impedance can be reconfigured by the proposed method.…”
Section: A Principle Of the Proposed Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…According to the equivalent circuit of the proposed impedance-matching based control, the reconstructed output impedance of the GCC can be obtained in (10). Comparing the original output impedance in (4) with the conventional double-loop control scheme, the zero and pole placement of the output impedance can be reconfigured by the proposed method.…”
Section: A Principle Of the Proposed Methodsmentioning
confidence: 99%
“…The basic idea is to introduce system state variables to achieve feedback control [9]. Examples of these state variables include the filter capacitor voltage [10], [11], the inverter-side inductor current [12], and the filter capacitor current [13]- [16]. Moreover, multiple-state feedback is also employed for active damping [17].…”
Section: Introductionmentioning
confidence: 99%
“…Typical applications of proportional i C1 feedback can be found in [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34]. For 1 storder derivative feedback of u C1 , a high-pass filter (HPF) with a similar response is an alternative solution [35].…”
Section: Ad Subject To Different Options Of Single Statementioning
confidence: 99%
“…Filter-based AD improves stability by adding a digital filter next to the current controller [11][12][13][14][15][16]. For feedbackbased AD, the state used for feedback can be the capacitor current [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32], the capacitor voltage [33][34][35][36], the inverterside current [37], the grid current [38][39][40][41] or a combination of multiple states [42][43][44][45][46][47][48][49][50]. Among the feedback-based AD methods, proportional feedback of capacitor current is widely studied during last decade due to its simple implementation.…”
Section: Introductionmentioning
confidence: 99%
“…APF containing two voltage inverters and medium voltage transformer Tr1 with a vector group of Dy5 compensates harmonic current drawn by the non-linear load in the form of Th12 converter. The chokes at the output of the inverter with the C capacitors and the leakage inductance of the transformer Tr1 form LCL filter type [17,18] in each phase.…”
Section: Description Of the Input Circuit Of Activementioning
confidence: 99%