2015
DOI: 10.1155/2015/871826
|View full text |Cite
|
Sign up to set email alerts
|

A Simple Predictive Method of Critical Flicker Detection for Human Healthy Precaution

Abstract: Interharmonics and flickers have an interrelationship between each other. Based on International Electrotechnical Commission (IEC) flicker standard, the critical flicker frequency for a human eye is located at 8.8 Hz. Additionally, eye strains, headaches, and in the worst case seizures may happen due to the critical flicker. Therefore, this paper introduces a worthwhile research gap on the investigation of interrelationship between the amplitudes of the interharmonics and the critical flicker for 50 Hz power s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…Then, the maximum and minimum of the rms value are optimised by using minmax function in the MATLAB/Simulink. Subsequently, the relative fluctuation voltage (d v / v ) is calculated as below [29]dvv=normalmaximumnormalminimum0.5(normalmaximum+normalminimum)×100 At the same time, the rms value is also analysed by short‐time Fourier transform (STFT) [30] with sliding window of 2560 samples and sampling frequency of 12,800 Hz. STFT is utilised to identify the frequency component in of the rms value.…”
Section: Signal Analysis With the Presence Of Second Harmonicmentioning
confidence: 99%
See 1 more Smart Citation
“…Then, the maximum and minimum of the rms value are optimised by using minmax function in the MATLAB/Simulink. Subsequently, the relative fluctuation voltage (d v / v ) is calculated as below [29]dvv=normalmaximumnormalminimum0.5(normalmaximum+normalminimum)×100 At the same time, the rms value is also analysed by short‐time Fourier transform (STFT) [30] with sliding window of 2560 samples and sampling frequency of 12,800 Hz. STFT is utilised to identify the frequency component in of the rms value.…”
Section: Signal Analysis With the Presence Of Second Harmonicmentioning
confidence: 99%
“…The first part is for analysing pure interrelationship between voltage flicker and harmonic. Next, voltage flicker analysis for critical voltage flicker waveform [29] is done in the second part. Finally, voltage flicker analysis for combination of critical voltage flicker and second harmonic are done in the third part.…”
Section: Experimental Validationmentioning
confidence: 99%