A simple method for simultaneous determination of nine triazines in drinking water

Abstract: A simple, effective, and economic method for determination of nine triazines (ametryn, atrazine, cyanazine, prometryn, propazine, simazine, simetryn, terbuthylazine, and terbutryn) in drinking water based on solid-phase extraction (SPE) followed by high-performance liquid chromatography-diode array detection (HPLC-DAD) was developed. A specialized solid phase (Oasis HLB) was used, and the parameters that may affect the efficiency of SPE were optimized. The limits of detection (ranged from 0.010 to 0.023 µg L −… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 40 publications
0
3
0
Order By: Relevance
“…The detection limit is 0.34 pM (S/N = 3), and the increase of the response signal by ATZ is 6.73 μA μcm –2 ·nM –1 , which is significantly higher than other homogeneous PEC sensing works (Table S3), showing high sensitivity of the proposed label-free and homogeneous PEC sensor. In addition, the detection limit of the sensor was far lower than some international standard of ATZ (European Union, 0.1 μg/L; United States Environmental Protection Agency, 3 μg/L; China’s Ministry of Health, 3 μg/L ). Meanwhile, the comparisons of ATZ determination performance by various methods also demonstrate the superior comprehensive performance of the constructed sensor (Table S2).…”
Section: Resultsmentioning
confidence: 83%
“…The detection limit is 0.34 pM (S/N = 3), and the increase of the response signal by ATZ is 6.73 μA μcm –2 ·nM –1 , which is significantly higher than other homogeneous PEC sensing works (Table S3), showing high sensitivity of the proposed label-free and homogeneous PEC sensor. In addition, the detection limit of the sensor was far lower than some international standard of ATZ (European Union, 0.1 μg/L; United States Environmental Protection Agency, 3 μg/L; China’s Ministry of Health, 3 μg/L ). Meanwhile, the comparisons of ATZ determination performance by various methods also demonstrate the superior comprehensive performance of the constructed sensor (Table S2).…”
Section: Resultsmentioning
confidence: 83%
“…The solid-phase extraction procedure was based on a previous method for drinking water developed by the same authors [28]. To optimize the method for surface waters, a filtration step prior to the SPE was studied.…”
Section: Resultsmentioning
confidence: 99%
“…High‐performance liquid chromatography (HPLC) is still the most commonly used technique for analyzing herbicides. Analytical HPLC methods with various detectors such as diode array detection (DAD), ultraviolet detection (UV), and mass spectrometry (MS) detection have been reported for the determination of atrazine. To quantify triazine by these methods, some authors have proposed several different approaches for preconcentration, extraction, and cleaning up.…”
Section: Introductionmentioning
confidence: 99%