2018
DOI: 10.3390/inventions3020021
|View full text |Cite
|
Sign up to set email alerts
|

A Simple ImageJ-Based Method to Measure Cardiac Rhythm in Zebrafish Embryos

Abstract: Zebrafish has an advantage of optical clarity within the body during its early developmental stage. Therefore, organs, including the heart, can be observed and analyzed in a non-invasive manner. Previously, heart rate measurement was analyzed by a complicated system, programming language, fluorescence transgenic zebrafish, or expensive setup that was not feasible and practical. In this study, we established a simple dissecting microscope with Charge-coupled Device (CCD) to capture the signal of heartbeat, and … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
54
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 36 publications
(57 citation statements)
references
References 35 publications
3
54
0
Order By: Relevance
“…Heart rate is defined as beats per minute (bpm) and can be obtained by multiplying the time interval (in seconds) between two peaks by a factor of 60. Furthermore, to validate the result of the heartbeat, the heart rate was measured directly from the heart by following a previously established ImageJ-based method [34].…”
Section: Blood Flow Pattern and Heart Rate Calculationmentioning
confidence: 99%
“…Heart rate is defined as beats per minute (bpm) and can be obtained by multiplying the time interval (in seconds) between two peaks by a factor of 60. Furthermore, to validate the result of the heartbeat, the heart rate was measured directly from the heart by following a previously established ImageJ-based method [34].…”
Section: Blood Flow Pattern and Heart Rate Calculationmentioning
confidence: 99%
“…The calculation principles and mathematical formulae for these cardiophysiological parameters are summarized in Figure 3 C–E. The use of a high-speed digital charged coupling device (CCD) and a Hoffman lens enabled the ventricle volume and other parameters to be measured with high precision in concordance with our previously published method [ 63 ]. A significant decrease in heart rate at the ventricle was observed after incubation at a sublethal dose of CuSO 4 at 10 nM, but this bradycardia phenotype was rescued if the Cu 2+ -exposed embryos were cotreated with a recombinant GHK tripeptide, even at the lowest concentration of 1 nM.…”
Section: Resultsmentioning
confidence: 70%
“…Furthermore, we also validate the result by recording at a different ambient temperature as D. magna used in this research have the ectothermic property [17,18]. We also uses astemizole to induce arrhythmia in zebrafish [10] and test whether our kymograph method is able to detect the corresponding cardiac performance changes.…”
Section: Introductionmentioning
confidence: 78%
“…This study aimed to develop a kymographbased method built in ImageJ platform [16] to provide a fast, easy-to-use and inexpensive one-stop method to obtain multiple cardiac performance endpoints with high accuracy for both Daphnia neonates and zebrafish embryos. To validate our method's accuracy, we compared the overall performance with a previously established method [10]. Furthermore, we also validate the result by recording at a different ambient temperature as D. magna used in this research have the ectothermic property [17,18].…”
Section: Introductionmentioning
confidence: 94%
See 1 more Smart Citation