A Simple Image Intensifier Prepared for the Transport of Nano-Ampere keV Ion Beams

Abstract: We introduce our handmade image intensiˆer for visualizing the beam proˆles of accelerated ion beams having energy and current in the order of keV and nano-amperes, respectively. The simple image intensiˆer comprising stainless steel meshes and a ‰uorescent screen has been designed for the transport of mm-size ion beams. The intensiˆer is easy to install in the beamline of a vacuum setup, because it is designed to attach on a con‰at ‰ange of ICF70. We have used the image intensiˆer to observe the beam proˆles … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2017
2017
2017
2017

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…The inset shows an illustration of the incident beam spot proˆle before collimation. In the beam spot proˆle of 3×3 mm 2 , dark lines originated from a stainless mesh, used as a secondary electron emitter, are visible 15) . To observe the incident beam spot prole after collimation and scattering of protons from the target surface, the image intensiˆer was replaced by a ‰uorescent screen made on the ITO glass plate, assembled with a micro-channel-plate (MCP) (F2807; Hamamatsu Photonics), shown in Fig.…”
Section: Preparation Of the Experimental Apparatusmentioning
confidence: 99%
See 2 more Smart Citations
“…The inset shows an illustration of the incident beam spot proˆle before collimation. In the beam spot proˆle of 3×3 mm 2 , dark lines originated from a stainless mesh, used as a secondary electron emitter, are visible 15) . To observe the incident beam spot prole after collimation and scattering of protons from the target surface, the image intensiˆer was replaced by a ‰uorescent screen made on the ITO glass plate, assembled with a micro-channel-plate (MCP) (F2807; Hamamatsu Photonics), shown in Fig.…”
Section: Preparation Of the Experimental Apparatusmentioning
confidence: 99%
“…1. The main part of the experimental setup was described elsewhere 14,15) ; thus, only a brief outline and the parts modiˆed for this experiment are discussed.…”
Section: Preparation Of the Experimental Apparatusmentioning
confidence: 99%