1997
DOI: 10.1002/(sici)1097-0231(199703)11:5<479::aid-rcm874>3.0.co;2-u
|View full text |Cite
|
Sign up to set email alerts
|

A Simple High Performance Liquid Chromatography/Ionspray Tandem Mass Spectrometry Method for the Direct Determination of Paraquat and Diquat in Water

Abstract: A method has been developed for the direct determination of paraquat and diquat in water samples. No sample preparation was required and analysis was done using high performance liquid chromatography coupled with ionspray tandem mass spectrometry. Heptafluorobutyric acid was used as the ion-pair agent. Further improvements in this method included the incorporation of an internal standard (caffeine). Using this method, detection limits of 5 and 1 µg/L were obtained for paraquat and diquat respectively. Recoveri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
30
0

Year Published

2000
2000
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(36 citation statements)
references
References 13 publications
6
30
0
Order By: Relevance
“…in the blank media. The reported detection limits are comparable to the previously reported methodology (Table 1) [30][31][32][33][34][35] and lower than the maximum value established by the United States Environmental Protection Agency (EPA) in drinking water.…”
Section: Calibration Graphsupporting
confidence: 81%
“…in the blank media. The reported detection limits are comparable to the previously reported methodology (Table 1) [30][31][32][33][34][35] and lower than the maximum value established by the United States Environmental Protection Agency (EPA) in drinking water.…”
Section: Calibration Graphsupporting
confidence: 81%
“…Also, the sensitivity of the proposed assay is almost same as those of LC-time of flight-MS [14], LC-electrospray ionization-MS [15] and LC-tandem MS [17]. Although the proposed assay is less sensitive than voltammetry [9] and GC-ion trap-MS [10], these methods required special and complex equipment.…”
Section: Optimization Of Chemiluminescence Conditionsmentioning
confidence: 93%
“…Several methods have been reported for the analysis of paraquat using colorimetry [6], spectrophotometry [7], voltammetry [8], capillary electrophoresis (CE) [9], gas chromatography (GC) [10,11], high-performance liquid chromatography (HPLC) with ultraviolet (UV) detection [12], post-column colorimetric detection [13] and mass spectrometry (MS) [14][15][16][17]. The colorimetry using hydrosulfite as a reagent is very simple and traditional assay for paraquat and has been used for on-site analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Heptafluorobutyric acid (HFBA) was chosen as the ion-pair reagent in the present work. As modifiers in reversed phase LC, HFBA could prolong retention via forming ion pair with cation of etimicin, as well as improve peak shape by suppressing the interactions of the ionic etimicin with the active silanol sites on the column [26,27]. Moreover, this acid was volatile and was compatible with LC-MS/MS.…”
Section: Conditions Of Lcmentioning
confidence: 99%