2006
DOI: 10.2116/analsci.22.259
|View full text |Cite
|
Sign up to set email alerts
|

A Simple and Sensitive Analytical Method for the Determination of Antimony in Environmental and Biological Samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
2
0
2

Year Published

2007
2007
2023
2023

Publication Types

Select...
3
3
3

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 24 publications
0
2
0
2
Order By: Relevance
“…Shuto et al (2006) published new REE data for W-2 and BIR-1. Tiwari et al (2006) developed a highly sensitive method for the determination of Sb and showed new data for AGV-1. Precision and accuracy of ICP-AES and ICP-MS results were evaluated using G-2, AGV-1 and GSR-3 (She et al 2006).…”
Section: Rock Reference Materialsmentioning
confidence: 99%
“…Shuto et al (2006) published new REE data for W-2 and BIR-1. Tiwari et al (2006) developed a highly sensitive method for the determination of Sb and showed new data for AGV-1. Precision and accuracy of ICP-AES and ICP-MS results were evaluated using G-2, AGV-1 and GSR-3 (She et al 2006).…”
Section: Rock Reference Materialsmentioning
confidence: 99%
“…Up to now, LCV has been used only as a reagent for determination of hydrogen peroxide in water [29], marine water [30], food and rainwater [31], antimony in various environmental and biological samples [32], nitrite in water and soil [33], cypermethrin insecticide in environmental and biological samples [34], copper in environmental samples like tap water, agricultural run plant materials [35], and pharmaceutical samples [35][36][37], detecting trace of blood and as an enhance ment reagent for footwear, tyre and fingerprint impression [38][39][40][41].…”
Section: Hs S Onamentioning
confidence: 99%
“…A espectrofotometria é uma técnica simples, rápida e versátil para a determinação de substâncias. Reagentes como, leucocristal de violeta (Tiwari et al, 2006) e vermelho de bromopirogalol (Rath et al, 1997) foram relatados para a determinação de quantidades traço de antimônio. Os métodos são sensíveis, mas têm baixa seletividade, reprodutibilidade e são aplicáveis apenas a amostras específicas (Tiwari et al, 2006).…”
Section: Determinação De Antimôniounclassified
“…A determinação de antimônio foi realizada como descrito por Tiwari et al, 2006. Alíquotas das amostras de antimônio receberam uma solução de iodato de potássio 1 % (m/v), seguido por adição de solução de ácido clorídrico 0,5 mol L -1 .…”
Section: Espectrofotometria Uv-visível Por Leucocristal De Violeta (Lcv)unclassified