A simple and robust UPLC-SRM/MS method to quantify urinary eicosanoids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
70
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 66 publications
(70 citation statements)
references
References 52 publications
0
70
0
Order By: Relevance
“…SPE involves using commercial columns pre-packed with various sorbents, which include the reversed-phase C18 (e.g., Sep-Pak, Waters Corp, Milford, MA [64, 69], polymer-based reversed phase materials (e.g., Oasis HLB, Waters Corp, Milford, MA [51, 52, 65, 70] and Strata-X, Phenomenex, Torrance, CA [54, 56]) and anion-exchange polymer-based resins [45, 53, 71, 72] cartridges. A reversed-phase C18 cartridge will allow specificity of retention based on the eicosanoids overall hydrophobicity.…”
Section: Analysis Of Oxygenated Fatty Acid Metabolitesmentioning
confidence: 99%
See 1 more Smart Citation
“…SPE involves using commercial columns pre-packed with various sorbents, which include the reversed-phase C18 (e.g., Sep-Pak, Waters Corp, Milford, MA [64, 69], polymer-based reversed phase materials (e.g., Oasis HLB, Waters Corp, Milford, MA [51, 52, 65, 70] and Strata-X, Phenomenex, Torrance, CA [54, 56]) and anion-exchange polymer-based resins [45, 53, 71, 72] cartridges. A reversed-phase C18 cartridge will allow specificity of retention based on the eicosanoids overall hydrophobicity.…”
Section: Analysis Of Oxygenated Fatty Acid Metabolitesmentioning
confidence: 99%
“…Alternative extraction procedures using ether [74], acetone/chloroform [64], hexane–isopropanol [75], and ethyl acetate/ethanol mixtures have been proposed for a wide range of tissues. LLE has proven to be a valid high-throughput alternative to SPE for the extraction of lipid metabolites from biological matrices such as urine samples [53, 76] and brain samples [64, 77]. Additionally, LLE can be used in combination with SPE to maximize the purification of oxygenated PUFA species prior to further MS analysis [66, 7880].…”
Section: Analysis Of Oxygenated Fatty Acid Metabolitesmentioning
confidence: 99%
“…In support, Piper (1988) reported increased basal levels of aldosterone in E+-exposed sheep. 12-HETE has been used as a urinary biomarker of hypertension and platelet activation (Sterz et al, 2012;Yeung and Holinstat, 2011) and has vasoconstrictive properties in the kidneys, where it increases in response to angiotensin II (Ma et al, 1991;Yiu et al, 2003), which is likely increased in FT (Oliver, 1997(Oliver, , 2005.…”
mentioning
confidence: 98%
“…To evaluate LC-MS/MS method performance, we validated our method in plasma and liver samples as described previously ( 26 ). Precisions showed CVs <15% for highabundant metabolites and CVs <20% for low-abundant compounds.…”
Section: Methods Applicationmentioning