2019
DOI: 10.1039/c8ra09230c
|View full text |Cite
|
Sign up to set email alerts
|

A SERS aptasensor for sensitive and selective detection of bis(2-ethylhexyl)phthalate

Abstract: This paper reports a SERS aptasensor developed to detect DEHP at relevant ranges with ultrasensitive performance and good selectivity.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
19
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(19 citation statements)
references
References 56 publications
0
19
0
Order By: Relevance
“…Tu et al designed a competitive binding assay for DEHP determination by aptamer modified MNPs and SERS silica particles [60]. On the one hand, the MNPs were functionalized with the DEHP aptamers by streptavidin–biotin interaction.…”
Section: Aptamer-based Sers Probes In Quantitative Analysis and Bimentioning
confidence: 99%
“…Tu et al designed a competitive binding assay for DEHP determination by aptamer modified MNPs and SERS silica particles [60]. On the one hand, the MNPs were functionalized with the DEHP aptamers by streptavidin–biotin interaction.…”
Section: Aptamer-based Sers Probes In Quantitative Analysis and Bimentioning
confidence: 99%
“…The resulting structure presents high selectivity for detection of malation in mixed solution of pesticides . The coating of cluster of Raman reporter molecules by silica favors the development or more stable SERS systems …”
Section: Theoretical Backgroundmentioning
confidence: 99%
“…43 The coating of cluster of Raman reporter molecules by silica favors the development or more stable SERS systems. 44 In addition to the modification of plasmonic centers, other important parameter to be considered in production of device refers to the substrate nature. 45…”
Section: Sers Mechanisms Sensors Selectivity and Applicationsmentioning
confidence: 99%
“…However, these methods are expensive, time-consuming, and have high LOD, which inhibit their application in the field for on-spot rapid detection. Alternatively, enzyme-linked immunosorbent assay (ELISA) has a LOD of 4.2 pg/mL [11], while the LOD is 3.9 pg/mL [12] for electrochemical aptasensor, 0.5 pg/mL for quantum dot aptasensor [13], and 8 pM for surface-enhanced raman spectroscopy (SERS) aptasensor [14]. The obvious advantages of these rapid-detection techniques are that they are fast, low-cost, and exhibit high selectivity and sensitivity in monitoring trace DEHP in samples.…”
mentioning
confidence: 99%
“…However, this detection technology was complex and was thus not used to detect real samples in their research. An aptasensor [14] based on SERS has also been developed with a LOD of 8 pM. However, this method included a series of procedures involving magnetic particles and silver nanoparticles with silica.…”
mentioning
confidence: 99%